Goodrive350-19 series VFD for crane
Basic operation guidelines
-137-
Function
code
Name
Description
Default
2: Static autotuning 1 (comprehensive autotuning);
static autotuning 1 is used in cases where the motor
cannot be disconnected from load.
3: Static autotuning 2 (partial autotuning); when the
present motor is motor 1, only P02.06, P02.07 and
P02.08 are autotuned; when the present motor is
motor 2, only P12.06, P12.07 and P12.08 are
autotuned.
P00.18
Function parameter
restore
0: No operation
1: Restore default values
2: Clear fault records
Note: After the selected operation is performed, the
function code is automatically restored to 0.
Restoring the default values may delete the user
password. Exercise caution when using this function.
0
P02.00
Type of motor 1
0: Asynchronous motor (AM)
1: Synchronous motor (SM)
0
P02.01
Rated power of AM
1
0.1
–3000.0kW
Model
depended
P02.02
Rated frequency of
AM 1
0.01Hz
–P00.03 (Max. output frequency)
50.00Hz
P02.03
Rated speed of AM
1
1
–36000rpm
Model
depended
P02.04
Rated voltage of AM
1
0
–1200V
Model
depended
P02.05
Rated current of AM
1
0.8
–6000.0A
Model
depended
P02.15
Rated power of SM
1
0.1
–3000.0kW
Model
depended
P02.16
Rated frequency of
SM 1
0.01Hz
–P00.03 (Max. output frequency)
50.00Hz
P02.17
Number of pole pairs
of SM 1
1
–50
2
P02.18
Rated voltage of SM
1
0
–1200V
Model
depended
P02.19
Rated current of SM
1
0.8
–6000.0A
Model
depended