Goodrive350-19 series VFD for crane
Function parameter list
-241-
Function
code
Name
Description
Default
Modify
Sin
FWD
REV
Running
direction
ON
OFF→ON
ON
FWD run
OFF
FWD run
ON
ON
OFF→ON
REV run
OFF
REV run
ON→OFF
DEC to
stop
Sin: Three-wire control; FWD: Forward running;
REV: Reverse running
Note: For two-wire controlled running mode,
when the FWD/REV terminal is valid, if the
VFD stops due to a stop command given by
another source, the VFD does not run again
after the stop command disappears even if
the control terminal FWD/REV is still valid.
To make the VFD run, you need to trigger
FWD/REV again, for example, PLC
single-cycle stop, fixed-length stop, and
valid STOP/RST stop during terminal control.
P05.12
S1 switch-on
delay
Used to specify the delay time corresponding to
the electrical level changes when the
programmable input terminals switch on or
switch off.
Si electrical level
Si valid
invalid
invalid
Switch-on
delay
Switch-off
delay
valid
Setting range: 0.000
–50.000s
Note: After a virtual terminal is enabled, the
state of the terminal can be changed only in
communication mode. The communication
address is 0x200A.
0.000s
○
P05.13
S1 switch-off
delay
0.000s
○
P05.14
S2 switch-on
delay
0.000s
○
P05.15
S2 switch-off
delay
0.000s
○
P05.16
S3 switch-on
delay
0.000s
○
P05.17
S3 switch-off
delay
0.000s
○
P05.18
S4 switch-on
delay
0.000s
○
P05.19
S4 switch-off
0.000s
○