Goodrive350-19 series VFD for crane
Commissioning guidelines
-80-
Function
code
Name
Description
Default
frequency
P90.18
Forward brake closing
frequency
0.00
–20.00Hz
3.00Hz
P90.19
Reverse brake closing
frequency
0.00
–20.00Hz
3.00Hz
P90.20
Delay before forward brake
release
0.000
–5.000s
0.300s
P90.21
Delay before reverse brake
release
0.000
–5.000s
The value 0 indicates the delay
before forward brake release is used.
0.000s
P90.22
Delay after forward brake
release
0.000
–5.000s
0.300s
P90.23
Delay after reverse brake
release
0.000
–5.000s
The value 0 indicates the delay after
forward brake release is used.
0.000s
P90.24
Delay before forward brake
closing
0.000
–5.000s
0.300s
P90.25
Delay before reverse brake
closing
0.000
–5.000s
The value 0 indicates the delay
before forward brake closing is used.
0.000s
P90.26
Delay after forward brake
closing
0.000
–5.000s
0.300s
P90.27
Delay after reverse brake
closing
0.000
–5.000s
The value 0 indicates the delay after
forward brake closing is used.
0.000s
P90.28
Retaining frequency for stop
0.00
–50.00Hz
5.00Hz
P90.29
Retaining frequency hold time
for stop
0.00
–5.000S
0.000s
P90.30
Torque verification fault
detection time
0.00
–10.000S
6.000s
P90.31
Enabling the monitoring on
brake status
0
–1
0: Disable
0
P90.32
Brake feedback exception delay
(brake feedback detection time)
0.00
–20.000S
1.000s
P90.33
Brake monitoring current
threshold
0.0%
–200.0%
100.0% corresponds to the motor
rated current.
100.0%