Goodrive350-19 series VFD for crane
Basic operation guidelines
-176-
S1
S2
S3
S4
HDIA
HD1B
P05.08 (input terminal polarity)
P05.01
P05.02
P05.03
P05.04
T delay
T delay
T delay
T delay
T delay
T delay
P05.13
P05.15
P05.17
P05.19
P05.21
P05.23
0
1
2
3
4
5
.
.
.
.
29
30
P05.09 (digital filter time)
(Default value is 1)
(Default value is 4)
(Default value is 7)
(Default value is 0)
(Default value is 0)
(Default value is 0)
P05.00
(HDI input type)
0
1
0
1 -1
0
1 -1
0
1 -1
0
1 -1
0
1 -1
0
1 -1
P17.11
Digital input
terminal state
P07.39
Input terminal
state of present
fault
Fault?
Fault
Run
Digital function selection
T delay
T delay
T delay
T delay
T delay
T delay
P05.12
P05.14
P05.16
P05.18
P05.20
P05.22
P05.05
P05.06
This parameter is used to set the corresponding function of digital multi-function input terminals.
Note: Two different multifunction input terminals cannot be configured with a same function.
Setting
Function
Description
0
No function
The VFD does not act even if there is signal input. Set
unused terminals to "no function” to avoid misaction.
1
Run forward
External terminals are used to control the forward/reverse
running of the VFD.
2
Run reversely
3
Three-wire running control
The terminal is used to determine the three-wire running
control of the VFD. For details, see description for P05.13.
4
Jog forward
For details about frequency of jogging running and
ACC/DEC time of jogging running, see the description for
P08.06, P08.07, and P08.08.
5
Jog reversely
6
Coast to stop
The VFD blocks output, and the stop process of motor is
uncontrolled by the VFD. This mode is applied in the
scenarios with large-inertia loads and without stop time
requirements.
Its definition is the same as P01.08, and it is mainly used in
remote control.
7
Fault reset
External fault reset function, same as the reset function of
the STOP/RST key on the keypad. You can use this
function to reset faults remotely.
8
Pause running
The VFD decelerates to stop, however, all the run
parameters are in memory state, such as PLC parameter,
wobbling frequency, and PID parameter. After this signal
disappears, the VFD will revert to the state before stop.
9
External fault input
When external fault signal is transmitted to the VFD, the
VFD releases fault alarm and stops.
10
Increase frequency setting Used to change the frequency increase/decrease command