Goodrive350-19 series VFD for crane
Commissioning guidelines
-64-
Function
code
Name
Setting
Remarks
commands
P00.06
Setting channel of A
frequency command
2
AI2
P00.07
Setting channel of B
frequency command
0
Keypad
P00.11
ACC time 1
10.0s
P00.12
DEC time 1
5.0s
P01.15
Stop speed
0.20 Hz
P03.25
Pre-exciting time
0.000
Disable pre-exciting.
P05.03
Function of S3
64
Upward position limit
P05.04
Function of S4
5
Fault reset
P05.29
AI2 lower limit
-10.00V
-10.00V
–P05.31
P05.30
Corresponding setting of
AI2 lower limit
100.0%
-300.0%
–300.0%
P05.31
AI2 middle value 1
-0.10V
P05.29
–P05.33
P05.32
Corresponding setting of
AI2 middle value 1
0.0%
-300.0%
–300.0%
P05.33
AI2 middle value 2
0.10V
P05.31
–P05.35
P05.34
Corresponding setting of
AI2 middle value 2
0.0%
-300.0%
–300.0%
P05.35
AI2 upper limit
10.00V
P05.33
–10.00V
P05.36
Corresponding setting of
AI2 upper limit
100.0%
-300.0%
–300.0%
P05.37
AI2 input filter time
0.100s
0.000s
–10.000s
P06.03
RO1 output
49
Brake output
P06.04
RO2 output
5
VFD in fault
P90.04
Enabling brake-oriented
logic
1
The brake is controlled by the VFD.
P90.14
Forward brake release
torque
50.0%
Corresponding to the motor rated
torque
P90.15
Reverse brake release
torque
50.0%
Corresponding to the motor rated
torque
P90.16
Forward brake release
frequency
1.00Hz
P90.17
Reverse brake release
frequency
1.00Hz
P90.18
Forward brake closing
1.00Hz