Goodrive350-19 series VFD for crane
Function parameter list
-316-
Function
code
Name
Description
Default
Modify
coefficient
P24.24
Motor pole pairs in
initial pole angle
autotuning
0
–128
2
◎
P25 group
––I/O card input functions
Function
code
Name
Description
Default
Modify
P25.01
Function of S5
Same as P05
0
◎
P25.02
Function of S6
0
◎
P25.03
Function of S7
0
◎
P25.04
Function of S8
0
◎
P25.05
Function of S9
0
◎
P25.06
Function of S10
0
◎
P25.07
Function of S11
0
◎
P25.08
Function of S12
0
◎
P25.10
Expansion card
input terminal
polarity
0x000
–0x1FF
BIT7
BIT6
BIT5
BIT4
S12
S11
S10
S9
BIT3
BIT2
BIT1
BIT0
S8
S7
S6
S5
0x000
○
P25.11
Expansion card
virtual terminal
setting
0x000
–0x1FF (0: Disable. 1: Enable)
BIT0: S5 virtual terminal
BIT1: S6 virtual terminal
BIT2: S7 virtual terminal
BIT3: S8 virtual terminal
BIT4: S9 virtual terminal
BIT5: S10 virtual terminal
BIT6: S11 virtual terminal
BIT7: S12 virtual terminal
BIT8: HDI3 virtual terminal
0x000
◎
P25.14
S5 switch-on
delay
Used to specify the delay time corresponding to
the electrical level changes when the
programmable input terminals switch on or
switch off.
0.000s
○
P25.15
S5 switch-off
delay
0.000s
○
P25.16
S6 switch-on
delay
0.000s
○