Goodrive350-19 series VFD for crane
Function parameter list
-225-
Function
code
Name
Description
Default
Modify
P03.34
Flux-weakening
control mode
selection
0
–0x111
Ones place: Control mode selection
0: Mode 0
1: Mode 1
2: Mode 2
Tens place: Compensation of inductance
saturation coefficient
0: Yes
1: No
Hundreds place: Reserved
0: Mode 0
1: Mode 1
0x000
○
P03.35
Control
optimization
setting
0
–0x1111
Ones place: Torque command selection
0: Torque giving
1: Torque current reference
Tens place: Reserved
0: Reserved Hundreds place: indicates whether
to enable speed-loop integral separation
0: Disable
1: Enable
Thousands place: Reserved
0: Reserved
1: Reserved
Range: 0x0000
–0x1111
0x0000
○
P03.36
Speed-loop
differential gain
0.00
–10.00s
0.00s
○
P03.37
High-frequency
current-loop
proportional
coefficient
In the closed-loop vector control mode
=3), when the frequency is lower than
the current-loop high-frequency switching
threshold (
), the current-loop PI
parameters are
; and when
the frequency is higher than the current-loop
high-frequency switching threshold, the
current-loop PI parameters are
setting range: 0
–65535
setting range: 0
–65535
1000
○
P03.38
High-frequency
current-loop
integral coefficient
1000
○
P03.39
Current-loop
high-frequency
switching
threshold
100.0%
○