Goodrive350-19 series VFD for crane
Function parameter list
-313-
Function
code
Name
Description
Default
Modify
encoder reversal
fault
Setting range: 0.0
–100.0s
P24.05
Filter times of
encoder detection
Setting range: 0x00
–0x99
Ones place: Low-speed filter time,
corresponding to 2^(0
–9)*125μs.
Tens place: High-speed filter times,
corresponding to 2^(0
–9)*125μs.
0x33
○
P24.06
Speed ratio
between encoder
mounting shaft
and motor
You need to set the function parameter when
the encoder is not installed on the motor shaft
and the drive ratio is not 1.
Setting range: 0.001
–65.535
1.000
○
P24.07
Control
parameters of SM
Bit0: Enable Z pulse calibration
Bit1: Enable encoder angle calibration
Bit2: Enable SVC speed measurement
Bit3: Reserved
Bit4: Reserved
Bit5: Reserved
Bit6: Enable the CD signal calibration
Bit7: Reserved
Bit8: Do not detect encoder faults during
autotuning
Bit9: Enable Z pulse detection optimization
Bit10: Enable the initial Z pulse calibration
optimization
Bit12: Clear the Z pulse arrival signal after stop
0x3
○
P24.08
Enable Z pulse
offline detection
0x00
–0x11
Ones place: Z pulse detection
0: Disable
1: Enable
Tens place: UVW pulse detection (for SM)
0: Disable
1: Enable
0x10
○
P24.09
Initial angle of Z
pulse
Relative electric angle between the encoder Z
pulse and the motor pole position.
Setting range: 0.00
–359.99
0.00
○
P24.10 Pole initial angle
Relative electric angle between the encoder
position and the motor pole position.
Setting range: 0.00
–359.99
0.00
○