Goodrive350-19 series VFD for crane
Commissioning guidelines
-83-
Function
code
Name
Description
Setting
(The reverse-running start direction
complies with the command.)
1: Enable
(The reverse-running start direction is
always the forward-running
direction.)
Tens place: indicates whether to
enable forward torque for
reverse-running stop
0: Disable
(The reverse-running stop direction
complies with the command.)
1: Enable
(The reverse-running stop direction is
always the forward-running
direction.)
P90.16
Forward brake release
frequency
0.00
–20.00Hz
3.00Hz
P90.17
Reverse brake release
frequency
0.00
–20.00Hz
3.00Hz
P90.18
Forward brake closing
frequency
0.00
–20.00Hz
3.00Hz
P90.19
Reverse brake closing
frequency
0.00
–20.00Hz
3.00Hz
P90.20
Delay before forward brake
release
0.000
–5.000s
0.300s
P90.21
Delay before reverse brake
release
0.000
–5.000s
The value 0 indicates the delay
before forward brake release is used.
0.000s
P90.22
Delay after forward brake
release
0.000
–5.000s
0.300s
P90.23
Delay after reverse brake
release
0.000
–5.000s
The value 0 indicates the delay after
forward brake release is used.
0.000s
P90.24
Delay before forward brake
closing
0.000
–5.000s
0.300s
P90.25
Delay before reverse brake
0.000
–5.000s
0.000s