Goodrive200 inverters Appendix C
255
escape from the breaker enclosure in case of a short-circuit. To ensure
safe use, special attention must be paid to the installation and
placement of the breakers. Follow the manufacturer’s instructions.
Inverter
Breaker (A)
Fuse (A)
Rated current of the
reactor (A)
GD200-1R5G-4
10
16
12
GD200-2R2G-4
16
16
12
GD200-004G/5R5P-4
16
25
12
GD200-5R5G/7R5P-4
25
32
25
GD200-7R5G/011P-4
40
40
25
GD200-011G/015P-4
50
50
40
GD200-015G/018P-4
63
63
40
GD200-018G/022P-4
63
80
50
GD200-022G/030P-4
80
100
65
GD200-030G/037P-4
100
125
80
GD200-037G/045P-4
125
160
95
GD200-045G/055P-4
160
160
115
GD200-055G/075P-4
160
200
150
GD200-075G/090P-4
250
250
185
GD200-090G/110P-4
250
315
225
GD200-110G/132P-4
315
315
265
GD200-132G/160P-4
350
400
330
GD200-160G/185P-4
400
500
400
GD200-185G/200P-4
500
630
500
GD200-200G/220P-4
500
630
500
GD200-220G/250P-4
630
630
500
GD200-250G/280P-4
630
800
630
GD200-280G/315P-4
700
800
630
GD200-315G/350P-4
800
1000
780
GD200-350G/400P-4
800
1000
780
GD200-400G-4
1000
1250
780
GD200-500G-4
1200
1250
980
Summary of Contents for GD200-037G/045P-4
Page 1: ...Goodrive 200 Inverter ...
Page 44: ...Goodrive200 inverters Keypad operation procedure 43 Fig 5 5 Sketch map of state watching ...
Page 158: ...Goodrive200 inverters Basic operation instruction 157 ...
Page 208: ...Goodrive200 inverters Fault tracking 207 8 6 2 Motor vibration 8 6 3 Overvoltage ...
Page 209: ...Goodrive200 inverters Fault tracking 208 8 6 4 Undervoltage fault 8 6 5 Inverter overheating ...
Page 210: ...Goodrive200 inverters Fault tracking 209 8 6 6 Abnormal motor heat ...
Page 211: ...Goodrive200 inverters Fault tracking 210 8 6 7 Stall during the acceleration of the motor ...
Page 266: ...1 1 0 0 1 0 0 7 7 9 6 6 0 0 1 0 0 0 9 5 201701 V2 2 ...