Goodrive200 inverters Function codes
70
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
The setting range of P04.01:0.0%:(automatic)
0.1%~10.0%
The setting range of P04.02:0.0%~50.0%
P04.03
V/F
frequency
1 of motor
1
When P04.00 =1, the user can set V//F curve
through P04.03~P04.08.
V/F is generally set according to the load of the
motor.
Note:
V1
<
V2
<
V3, f1
<
f2
<
f3. Too high low
frequency voltage will heat the motor excessively
or damage. The inverter may occur the
overcurrent speed or overcurrent protection.
The setting range of P04.03: 0.00Hz~P04.05
The setting range of P04.04:0.0%~110.0%
The setting range of P04.05:P04.03~ P04.07
The setting range of P04.06:0.0%~110.0%
(the rated voltage of motor 1)
The setting range of P04.07:P04.05~ P02.02
(the rated frequency of motor 1)
The setting range of P04.08:0.0%~110.0%
0.00Hz
○
P04.04
V/F voltage
1 of motor
1
00.0%
○
P04.05
V/F
frequency
2 of motor
1
00.00Hz
○
P04.06
V/F voltage
2 of motor
1
00.0%
○
P04.07
V/F
frequency
3 of motor
1
00.00Hz
○
P04.08
V/F voltage
3 of motor
1
00.0%
○
Summary of Contents for GD200-037G/045P-4
Page 1: ...Goodrive 200 Inverter ...
Page 44: ...Goodrive200 inverters Keypad operation procedure 43 Fig 5 5 Sketch map of state watching ...
Page 158: ...Goodrive200 inverters Basic operation instruction 157 ...
Page 208: ...Goodrive200 inverters Fault tracking 207 8 6 2 Motor vibration 8 6 3 Overvoltage ...
Page 209: ...Goodrive200 inverters Fault tracking 208 8 6 4 Undervoltage fault 8 6 5 Inverter overheating ...
Page 210: ...Goodrive200 inverters Fault tracking 209 8 6 6 Abnormal motor heat ...
Page 211: ...Goodrive200 inverters Fault tracking 210 8 6 7 Stall during the acceleration of the motor ...
Page 266: ...1 1 0 0 1 0 0 7 7 9 6 6 0 0 1 0 0 0 9 5 201701 V2 2 ...