Fault code
Fault type
Possible cause
What to do
OUt1
IGBT Ph-U fault
The acceleration is too
fast
IGBT module fault
Misaction caused by
interference
The connection of the
driving wires is not good,
Grounding is not properly
Increase Acc time
Change the power unit
Check the driving wires
Inspect external
equipment and eliminate
interference
OUt2
IGBT Ph-V fault
OUt3
IGBT Ph-W fault
OC1
Over-current when
acceleration
The acceleration or
deceleration is too fast
The voltage of the grid is
too low
The power of the inverter
is too low
The load transients or is
abnormal
The grounding is short
circuited or the output is
phase loss
There is strong external
interference
The overvoltage stall
protection is not open
Increase the ACC time
Check the input power
Select the inverter with a
larger power
Check if the load is short
circuited (the grounding
short circuited or the wire
short circuited) or the
rotation is not smooth
Check the output
configuration.
Check if there is strong
interference
Check the setting of
relative function codes
OC2
Over-current when
deceleration
OC3
Over-current when
constant speed
running
OV1
Over-voltage
when acceleration
The input voltage is
abnormal
There is large energy
feedback
No braking components
Braking energy is not open
Check the input power
Check if the DEC time of
the load is too short or the
inverter starts during the
rotation of the motor or it
needs to add the dynamic
braking components
Install the braking
components
Check the setting of
relative function codes
OV2
Over-voltage
when deceleration
OV3
Over-voltage
when constant
speed running
UV
DC bus
Under-voltage
The voltage of the power
supply is too low
The overvoltage stall
protection is not open
Check the input power of
the supply line
Check the setting of
relative function codes
Summary of Contents for GD200-037G/045P-4
Page 1: ...Goodrive 200 Inverter ...
Page 44: ...Goodrive200 inverters Keypad operation procedure 43 Fig 5 5 Sketch map of state watching ...
Page 158: ...Goodrive200 inverters Basic operation instruction 157 ...
Page 208: ...Goodrive200 inverters Fault tracking 207 8 6 2 Motor vibration 8 6 3 Overvoltage ...
Page 209: ...Goodrive200 inverters Fault tracking 208 8 6 4 Undervoltage fault 8 6 5 Inverter overheating ...
Page 210: ...Goodrive200 inverters Fault tracking 209 8 6 6 Abnormal motor heat ...
Page 211: ...Goodrive200 inverters Fault tracking 210 8 6 7 Stall during the acceleration of the motor ...
Page 266: ...1 1 0 0 1 0 0 7 7 9 6 6 0 0 1 0 0 0 9 5 201701 V2 2 ...