Goodrive200 inverters Function codes
119
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
ACC/DEC
time
Functio
n code
Binary bit
Step
ACC/DE
C 0
ACC/DE
C 1
ACC/DE
C 2
ACC/DE
C 3
P10.34
BIT1 BIT0
0
00
01
10
11
BIT3 BIT2
1
00
01
10
11
BIT5 BIT4
2
00
01
10
11
BIT7 BIT6
3
00
01
10
11
BIT9 BIT8
4
00
01
10
11
BIT11 BIT10
5
00
01
10
11
BIT13 BIT12
6
00
01
10
11
BIT15 BIT14
7
00
01
10
11
P10.35
BIT1 BIT0
8
00
01
10
11
BIT3 BIT2
9
00
01
10
11
BIT5 BIT4
10
00
01
10
11
BIT7 BIT6
11
00
01
10
11
BIT9 BIT8
12
00
01
10
11
BIT11 BIT10
13
00
01
10
11
BIT13 BIT12
14
00
01
10
11
BIT15 BIT14
15
00
01
10
11
After the users select the corresponding
ACC/DEC time, the combined 16 binary bits will
change into decimal bit, and then set the
corresponding function codes.
Setting range: 0x0000~0xFFFF
P10.35
Simple
PLC 8~15
step
ACC/DEC
time
0x0000
○
P10.36 PLC restart
0: Restart from the first step; stop during running
(cause by the stop command, fault or power
loss), run from the first step after restart.
1: Continue to run from the stop frequency; stop
during running(cause by stop command and
fault), the inverter will record the running time
automatically, enter into the step after restart and
keep the remaining running at the setting
0
◎
Summary of Contents for GD200-037G/045P-4
Page 1: ...Goodrive 200 Inverter ...
Page 44: ...Goodrive200 inverters Keypad operation procedure 43 Fig 5 5 Sketch map of state watching ...
Page 158: ...Goodrive200 inverters Basic operation instruction 157 ...
Page 208: ...Goodrive200 inverters Fault tracking 207 8 6 2 Motor vibration 8 6 3 Overvoltage ...
Page 209: ...Goodrive200 inverters Fault tracking 208 8 6 4 Undervoltage fault 8 6 5 Inverter overheating ...
Page 210: ...Goodrive200 inverters Fault tracking 209 8 6 6 Abnormal motor heat ...
Page 211: ...Goodrive200 inverters Fault tracking 210 8 6 7 Stall during the acceleration of the motor ...
Page 266: ...1 1 0 0 1 0 0 7 7 9 6 6 0 0 1 0 0 0 9 5 201701 V2 2 ...