Goodrive200
inverters Basic operation instruction
136
issue.
Besides P00.01 and P00.02, terminal command setting can also used to set the running command
channel.
Current running
command
channel
P00.01
Multi-function
terminal 36
Shifting the
command to keypad
Multi-function
terminal 37
Shifting the
command to
communication
Multi-function
terminal 38
Shifting the
command to
communication
Keypad running
command channel
/
Terminal running
command channel
Communication
running command
channel
Terminal running
command channel
Keypad running
command channel
/
Communication
running command
channel
Communication
running command
channel
Keypad running
command channel
Terminal running
command channel
/
Note:
“
/
”
means the multi-function terminal is invalid on the current reference channel.
Relative parameters table:
Function
code
Name
Detailed instruction of parameters
Default
value
P00.00
Speed control mode
1: SVC
2: SVPWM control (applying to AM)
2
P00.01
Run command channel
0:Keypad running command channel
(LED off)
1:Terminal running command channel
(LED flickering)
2:Communication running command
channel (LED on)
0
P00.02
Communication running
commands
0:MODBUS communication channel
1~ 3:Reserved
0
P00.18
Function
restore parameter
0:No operation
1:Restore the default value
2:Clear fault records
0
Summary of Contents for GD200-037G/045P-4
Page 1: ...Goodrive 200 Inverter ...
Page 44: ...Goodrive200 inverters Keypad operation procedure 43 Fig 5 5 Sketch map of state watching ...
Page 158: ...Goodrive200 inverters Basic operation instruction 157 ...
Page 208: ...Goodrive200 inverters Fault tracking 207 8 6 2 Motor vibration 8 6 3 Overvoltage ...
Page 209: ...Goodrive200 inverters Fault tracking 208 8 6 4 Undervoltage fault 8 6 5 Inverter overheating ...
Page 210: ...Goodrive200 inverters Fault tracking 209 8 6 6 Abnormal motor heat ...
Page 211: ...Goodrive200 inverters Fault tracking 210 8 6 7 Stall during the acceleration of the motor ...
Page 266: ...1 1 0 0 1 0 0 7 7 9 6 6 0 0 1 0 0 0 9 5 201701 V2 2 ...