Goodrive200 inverters Function codes
95
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
code 3
P07.24
Factory bar
code 4
0x0000~0xFFFF
●
P07.25
Factory bar
code 5
0x0000~0xFFFF
●
P07.26
Factory bar
code 6
0x0000~0xFFFF
●
P07.27
Current
fault type
0:No fault
1:IGBT U phase protection(OUt1)
2:IGBT V phase protection(OUt2)
3:IGBT W phase protection(OUt3)
4:OC1
5:OC2
6:OC3
7:OV1
8:OV2
9:OV3
10:UV
11:Motor overload(OL1)
12:The inverter overload(OL2)
13:Input side phase loss(SPI)
14:Output side phase loss(SPO)
15:Overheat of the rectifier module(OH1)
16:Overheat fault of the inverter module(OH2)
17:External fault(EF)
18:485 communication fault(CE)
19:Current detection fault(ItE)
20:Motor antotune fault(tE)
21:EEPROM operation fault(EEP)
22:PID response offline fault(PIDE)
23:Braking unit fault(bCE)
●
P07.28
Previous
fault type
●
P07.29
Previous 2
fault type
●
P07.30
Previous 3
●
Summary of Contents for GD200-037G/045P-4
Page 1: ...Goodrive 200 Inverter ...
Page 44: ...Goodrive200 inverters Keypad operation procedure 43 Fig 5 5 Sketch map of state watching ...
Page 158: ...Goodrive200 inverters Basic operation instruction 157 ...
Page 208: ...Goodrive200 inverters Fault tracking 207 8 6 2 Motor vibration 8 6 3 Overvoltage ...
Page 209: ...Goodrive200 inverters Fault tracking 208 8 6 4 Undervoltage fault 8 6 5 Inverter overheating ...
Page 210: ...Goodrive200 inverters Fault tracking 209 8 6 6 Abnormal motor heat ...
Page 211: ...Goodrive200 inverters Fault tracking 210 8 6 7 Stall during the acceleration of the motor ...
Page 266: ...1 1 0 0 1 0 0 7 7 9 6 6 0 0 1 0 0 0 9 5 201701 V2 2 ...