Goodrive200
inverters Basic operation instruction
148
Function
code
Name
Detailed instruction of parameters
Default
value
reverse rotation in
vector control
3: AI3
4:Pulse frequency HDI setting upper-limit
frequency
5:Multi-step setting upper-limit frequency
6:MODBUS communication setting upper-limit
frequency
7~9: Reserved
P03.16
Keypad setting for
upper frequency of
forward rotation
0.00Hz~P00.03 (the Max. frequency)
50.00 Hz
P03.17
Keypad setting for
upper frequency of
reverse rotation
0.00 Hz~P00.03 (the Max. frequency)
50.00 Hz
P03.18
Upper
electromotion
torque
source
0:Keypad setting upper-limit frequency(P03.20
sets P03.18, P03.21 sets P03.19)
1: AI1
2: AI2
3: AI3
4: HDI
5:MODBUS communication
6~8: Reserved
0
P03.19
Upper braking
torque
source
0
P03.20
Keypad setting of
electromotion
torque
0.0~300.0%( rated current of the motor)
180.0%
P03.21
Keypad setting of
braking torque
0.0~300.0%( rated current of the motor)
180.0%
P17.09
Output torque
-250.0~250.0%
0.0%
P17.15
Torque reference -300.0~300.0%( rated current of the motor)
0.0%
Summary of Contents for GD200-037G/045P-4
Page 1: ...Goodrive 200 Inverter ...
Page 44: ...Goodrive200 inverters Keypad operation procedure 43 Fig 5 5 Sketch map of state watching ...
Page 158: ...Goodrive200 inverters Basic operation instruction 157 ...
Page 208: ...Goodrive200 inverters Fault tracking 207 8 6 2 Motor vibration 8 6 3 Overvoltage ...
Page 209: ...Goodrive200 inverters Fault tracking 208 8 6 4 Undervoltage fault 8 6 5 Inverter overheating ...
Page 210: ...Goodrive200 inverters Fault tracking 209 8 6 6 Abnormal motor heat ...
Page 211: ...Goodrive200 inverters Fault tracking 210 8 6 7 Stall during the acceleration of the motor ...
Page 266: ...1 1 0 0 1 0 0 7 7 9 6 6 0 0 1 0 0 0 9 5 201701 V2 2 ...