EIRx-Sx series-0106 - 1/2
International Headquarters:
707 Dayton Road PO Box 1040 Ottawa, IL 61350 USA
815-433-5100 Fax 433-5104
www.bb-elec.com [email protected] [email protected]
European Headquarters:
Westlink Commercial Park Oranmore Co. Galway Ireland
+353 91 792444 Fax +353 91 792445
www.bb-europe.com [email protected] [email protected]
PRODUCT INFORMATION
B&B E
LE
C
TR
ONICS
Hardened Compact
Media Converter
This quick installation guide describ d compact Media
Converter.
Capable of operating at temperature
extremes of -34 to +74°C, this is the media converter
choice for harsh environments constrained by space.
100BaseFX Connections:
The Tx (transmit) port
of device 1 is connected to the Rx
(receive) port of device 2, and the
Rx (receive) port of device 1 to
the Tx (transmit) port of device 2.
Physical Description
Terminal Block and Power Inputs
10/100BaseTX and 100BaseFX Connectors
10/100BaseTX Connections:
Pin Regular Ports
Uplink Port
1
Receive Data + (input)
Transmit Data + (output)
2
Receive Data – (input)
Transmit Data – (output)
3
Transmit Data + (output)
Receive Data + (input)
4
NC
NC
5
NC
NC
6
Transmit Data – (output)
Receive Data – (input)
7
NC
NC
8
NC
NC
LED’s and DIP Switch
LED Status:
LEDs State Indication
Steady
Power or ports function abnormally
FAULT
Off Power
and
ports
function
normally
Steady Power
on
(PWR stands for POWER)
PWR1
PWR2
Off Power
off
Steady 100Mbps
network
connection
10/100
Off 10Mbps
network
connection
Steady LFPT
function
enabled
LFP
Off LFPT
function
disabled
Steady Network
connection
established
(LNK stands for LINK)
Flashing
Transmitting or receiving data
(ACT stands for ACTIVITY)
LNK/ACT
Off
Neither a network connection established nor
transmitting/receiving data
Steady
Connection in full duplex mode
(FDX stands for FULL-DUPLEX)
Flashing Collision
occurred
(COL stands for COLLISION)
FDX/COL
Off
Connection in half-duplex mode
DIP Switch Settings:
Pos.
Down(0)
Up(1)
1
Disable Link-fault-pass-through
Enable Link-fault-pass-through
2
RJ45 Auto Negotiation Enabled
RJ45 Forced Mode
3
RJ45 Forced to 100Mbps
RJ45 Forced to 10Mbps
4
RJ45 Forced to Full Duplex
RJ45 Forced to Half Duplex
5
Fiber Forced to Full Duplex
Fiber Forced to Half Duplex
6
Disable Link Down Alarm
Enable Link Down Alarm
This quick installation guide describes how to install and
use the hardened compact Media Converter.
Capable of
operating at temperature extremes of -34 to +74°C, this
is the media converter of choice for harsh environments
constrained by space.
Terminal Block Assignment
PWR1
Power Input 1 (10 to 48VDC)
GND
Power Ground
PWR2
Power Input 2 (10 to 48VDC)
GND
Power Ground
Earth Ground
FAULT
1. The relay opens if PWR1 or PWR2 fails
2. The relay opens if the Port Link is Down
(When the Link Down Alarm is Enabled)
While only one power source is
required to power up the media
converter, two power sources offer
redundancy for those mission critical
applications. (PWR1 and PWR2)
The terminals labeled Fault are
connected to a dry contact. The dry
contact is normally closed when either
power source is connected and active.
When no power is applied, the dry
contact is normally open.