background image

EIRx-Sx series-0106 - 1/2 

 

 

 

 

International Headquarters: 

 707 Dayton Road  PO Box 1040  Ottawa, IL 61350  USA 

815-433-5100  Fax 433-5104    

www.bb-elec.com    [email protected]   [email protected] 

 

European Headquarters:

   Westlink Commercial Park   Oranmore  Co. Galway  Ireland 

+353 91 792444   Fax +353 91 792445   

www.bb-europe.com   [email protected]  [email protected]

 

PRODUCT INFORMATION

                    

           

           

                     

              B&B E

LE

C

TR

ONICS

 

 
Hardened  Compact 
  Media  Converter 

 

 

This quick installation guide describ d compact Media 
Converter. 

Capable of operating at temperature 

extremes of -34 to +74°C, this is the media converter  
choice for harsh environments constrained by space. 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 

 

100BaseFX Connections:

 

 

The Tx (transmit) port  
of device 1 is connected to the Rx 
(receive) port of device 2, and the 
Rx (receive) port of device 1 to 
the Tx (transmit) port of device 2.

 

 
 

 

 

Physical Description

Terminal Block and Power Inputs 

 
 
 
    
 
 
 
 
 

 

     

                                                        

10/100BaseTX and 100BaseFX Connectors

10/100BaseTX Connections:

 

  Pin    Regular Ports 

  Uplink Port 

  Receive Data + (input) 

  Transmit Data + (output) 

  Receive Data – (input) 

  Transmit Data – (output) 

  Transmit Data + (output) 

  Receive Data + (input) 

  NC 

  NC 

  NC 

  NC 

  Transmit Data – (output) 

  Receive Data – (input) 

  NC 

  NC 

  NC 

  NC 

 

 

 

 

LED’s and DIP Switch  

LED Status: 

 

LEDs State Indication 

Steady 

Power or ports function abnormally  

FAULT 

Off Power 

and 

ports 

function 

normally 

Steady Power 

on 

 

(PWR stands for POWER)

 

PWR1 
PWR2 

Off Power 

off 

Steady 100Mbps 

network 

connection 

10/100  

Off 10Mbps 

network 

connection 

Steady LFPT 

function 

enabled 

LFP 

Off LFPT 

function 

disabled 

Steady Network 

connection 

established

(LNK stands for LINK) 

Flashing 

Transmitting or receiving data

(ACT stands for ACTIVITY) 

LNK/ACT 

Off 

Neither a network connection established nor 
transmitting/receiving data 

Steady 

Connection in full duplex mode

(FDX stands for FULL-DUPLEX) 

Flashing Collision 

occurred

(COL stands for COLLISION) 

FDX/COL 

Off 

Connection in half-duplex mode 

 

 

DIP Switch Settings: 

 

 Pos. 

Down(0) 

Up(1) 

 Disable Link-fault-pass-through 

 Enable Link-fault-pass-through 

 RJ45 Auto Negotiation Enabled 

 RJ45 Forced Mode 

 RJ45 Forced to 100Mbps 

 RJ45 Forced to 10Mbps 

 RJ45 Forced to Full Duplex 

 RJ45 Forced to Half Duplex 

 Fiber Forced to Full Duplex 

 Fiber Forced to Half Duplex 

 Disable Link Down Alarm 

 Enable Link Down Alarm 

 

 

This quick installation guide describes how to install and 
use the hardened compact Media Converter. 

Capable of 

operating at temperature extremes of -34 to +74°C, this 
is the media converter of choice for harsh environments 
constrained by space. 

 

 

Terminal Block Assignment 

PWR1 

  Power Input 1 (10 to 48VDC) 

GND 

  Power Ground 

PWR2 

  Power Input 2 (10 to 48VDC) 

GND 

  Power Ground 

 

  Earth Ground 

  

FAULT  

 1.  The relay opens if PWR1 or PWR2 fails 
 2.  The relay opens if the Port Link is Down 

      (When the Link Down Alarm is Enabled) 

While only one power source is 
required to power up the media 
converter, two power sources offer 
redundancy for those mission critical 
applications. (PWR1 and PWR2) 
 
The terminals labeled Fault are 
connected to a dry contact. The dry 
contact is normally closed when either 
power source is connected and active.  
When no power is applied, the dry 
contact is normally open. 

 