Intel® Server Board S2600CW Family TPS
Appendix F: POST Error Code
Revision 2.4
189
Error Code
Error Message
Response
85EC
DIMM_O3 encountered a Serial Presence Detection (SPD) failure
Major
85ED
DIMM_P1 encountered a Serial Presence Detection (SPD) failure
Major
85EE
DIMM_P2 encountered a Serial Presence Detection (SPD) failure
Major
85EF
DIMM_P3 encountered a Serial Presence Detection (SPD) failure
Major
8604
POST Reclaim of non-critical NVRAM variables
Minor
8605
BIOS Settings are corrupted
Major
92A3
Serial port component was not detected
Major
92A9
Serial port component encountered a resource conflict error
Major
A000
TPM device not detected.
Minor
A001
TPM device missing or not responding.
Minor
A002
TPM device failure.
Minor
A003
TPM device failed self-test.
Minor
A100
BIOS ACM Error
Major
A421
PCI component encountered a SERR error
Fatal
A5A0
PCI Express* component encountered a PERR error
Minor
A5A1
PCI Express* component encountered an SERR error
Fatal
The following table lists the POST error beep codes. Prior to system video initialization, the
BIOS uses these beep codes to inform users on error conditions. The beep code is followed by
a user-visible code on the POST Progress LEDs.
Table 97. POST Error Beep Codes
Beeps
Error Message
POST Progress Code
Description
3
Memory error
System halted because a fatal error related to the memory
was detected.
1 long
Intel
®
TXT security
violation
0xAE, 0xAF
System halted because Intel
®
Trusted Execution
Technology detected a potential violation of system
security.
POST Error Beep Code
The Integrated BMC may generate beep codes upon detection of failure conditions. Beep
codes are sounded each time the problem is discovered, such as on each power-up attempt,
but are not sounded continuously. Codes that are common across all Intel
®
Server Boards and
Systems that use same generation chipset are listed in the following table. Each digit in the
code is represented by a sequence of beeps whose count is equal to the digit.
Table 98. Integrated BMC Beep Codes
Code
Reason for Beep
Associated Sensors
1-5-2-1 No CPUs installed or first CPU socket is
empty.