Appendix C: BMC Sensor Tables
Intel® Server Board S2600CW Family TPS
158
Revision 2.4
Full Sensor Name
(Sensor name in SDR)
Senso
r #
Platform
Applicabili
ty
Sensor Type
Event/Rea
ding Type
Event Offset
Triggers
Contrib. To
System
Status
Assert
/De-
assert
Readab
le
Value/
Offsets
Event
Data
Rearm Stand-
by
06 – Non-Redundant:
degraded from fully
redundant.
Degraded
07 - Redundant
degraded from non-
redundant
Degraded
SSB Thermal Trip
(SSB Therm Trip)
0Dh
All
Temperature
01h
Digital
Discrete
03h
01 – State Asserted
Fatal
As
and
De
–
Trig Offset
M
X
IO Module Presence
(IO Mod Presence)
0Eh
Platform-
specific
Module/Board
15h
Digital
Discrete
08h
01 – Inserted/Present
OK
As
and
De
–
Trig Offset
M
-
SAS Module Presence
(SAS Mod Presence)
0Fh
Platform-
specific
Module/Board
15h
Digital
Discrete
08h
01 – Inserted/Present
OK
As
and
De
–
Trig Offset
M
X
BMC Firmware Health
(BMC FW Health)
10h
All
Mgmt Health
28h
Sensor
Specific
6Fh
04 – Sensor Failure
Degraded
As
-
Trig Offset
A
X
System Airflow
(System Airflow)
11h
All
Other Units
0Bh
Threshold
01h
–
–
–
Analog
–
–
–
FW Update Status
12h
All
Version Change
2Bh
OEM
defined
70h
00h
–
Update started
01h
–
Update
completed
successfully.
02h – Update failure
OK
As
_
Trig Offset
A
_
IO Module2 Presence
(IO Mod2 Presence)
13h
Platform-
specific
Module/Board
15h
Digital
Discrete
08h
01 – Inserted/Present
OK
As
and
De
–
Trig Offset
M
-