Appendix C: BMC Sensor Tables
Intel® Server Board S2600CW Family TPS
164
Revision 2.4
Full Sensor Name
(Sensor name in SDR)
Senso
r #
Platform
Applicabili
ty
Sensor Type
Event/Rea
ding Type
Event Offset
Triggers
Contrib. To
System
Status
Assert
/De-
assert
Readab
le
Value/
Offsets
Event
Data
Rearm Stand-
by
Processor 3 Thermal
Control %
(
P3 Therm Ctrl %
)
7Ah
Platform-
specific
Temperature
01h
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-fatal
As
and
De
Analog
Trig Offset
A
–
Processor 4 Thermal
Control %
(
P4 Therm Ctrl %
)
7Bh
Platform-
specific
Temperature
01h
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-fatal
As
and
De
Analog
Trig Offset
A
–
Processor ERR2 Timeout
(CPU ERR2)
7Ch
All
Processor
07h
Digital
Discrete
03h
01 – State Asserted
Fatal
As
and
De
–
Trig Offset
A
–
Catastrophic Error
(CATERR)
80h
All
Processor
07h
Digital
Discrete
03h
01 – State Asserted
Fatal
As
and
De
–
Trig Offset
M
–
MTM Level Change
(MTM Lvl Change)
81h
All
Mgmt Health
28h
Digital
Discrete
03h
01 – State Asserted
-
As
and
De
–
Trig Offset
A
-
Processor Population Fault
(CPU Missing)
82h
All
Processor
07h
Digital
Discrete
03h
01 – State Asserted
Fatal
As
and
De
–
Trig Offset
M
–
Processor 1 DTS Thermal
Margin
(P1 DTS Therm Mgn)
83h
All
Temperature
01h
Threshold
01h
-
-
-
Analog
R, T
A
–
Processor 2 DTS Thermal
Margin
(P2 DTS Therm Mgn)
84h
All
Temperature
01h
Threshold
01h
-
-
-
Analog
R, T
A
–
Processor 3 DTS Thermal
Margin
(P3 DTS Therm Mgn)
85h
Platform
Specific
Temperature
01h
Threshold
01h
-
-
-
Analog
R, T
A
–