Intel® Server Board S2600CW Family TPS
Appendix C: BMC Sensor Tables
Revision 2.4
157
Full Sensor Name
(Sensor name in SDR)
Senso
r #
Platform
Applicabili
ty
Sensor Type
Event/Rea
ding Type
Event Offset
Triggers
Contrib. To
System
Status
Assert
/De-
assert
Readab
le
Value/
Offsets
Event
Data
Rearm Stand-
by
System Event
(System Event)
08h
All
System Event
12h
Sensor
Specific
6Fh
04 – PEF action
OK
As
-
Trig Offset
A
X
Button Sensor
(Button)
09h
All
Button/Switch
14h
Sensor
Specific
6Fh
00 – Power Button
02 – Reset Button
OK
AS
_
Trig Offset
A
X
BMC Watchdog
0Ah
All
Mgmt System
Health
28h
Digital
Discrete
03h
01 – State Asserted
Degraded
As
–
Trig Offset
A
-
Voltage Regulator Watchdog
(VR Watchdog)
0Bh
All
Voltage
02h
Digital
Discrete
03h
01 – State Asserted
Fatal
As
and
De
–
Trig Offset
M
X
Fan Redundancy
1
(Fan Redundancy)
0Ch
Chassis-
specific
Fan
04h
Generic
0Bh
00 - Fully redundant
OK
As
and
De
–
Trig Offset
A
–
01 - Redundancy lost
Degraded
02 - Redundancy
degraded
Degraded
03 - Non-redundant:
Sufficient resources.
Transition from
redundant
Degraded
04 - Non-redundant:
Sufficient resources.
Transition from
insufficient.
Degraded
05 - Non-redundant:
insufficient resources.
Non-Fatal