Intel® Server Board S2600CW Family TPS
Appendix C: BMC Sensor Tables
Revision 2.4
155
Note
: All sensors listed below may not be present on all platforms. Check platform EPS section for platform applicability and
platform chassis section for chassis specific sensors. Redundancy sensors are present only on systems with appropriate hardware
to support redundancy (for instance, fan or power supply).
Table 91. Integrated BMC Core Sensors
Full Sensor Name
(Sensor name in SDR)
Senso
r #
Platform
Applicabili
ty
Sensor Type
Event/Rea
ding Type
Event Offset
Triggers
Contrib. To
System
Status
Assert
/De-
assert
Readab
le
Value/
Offsets
Event
Data
Rearm Stand-
by
Power Unit Status
(Pwr Unit Status)
01h
All
Power Unit
09h
Sensor
Specific
6Fh
00 - Power down
OK
As
and
De
–
Trig Offset
A
X
02 - 240 VA power
down
Fatal
04 - A/C lost
OK
05 - Soft power
control failure
Fatal
06 - Power unit failure
Power Unit Redundancy
1
(Pwr Unit Redund)
02h
Chassis-
specific
Power Unit
09h
Generic
0Bh
00 - Fully Redundant
OK
As
–
Trig Offset
M
X
01 - Redundancy lost
Degraded
02 - Redundancy
degraded
Degraded
03 - Non-redundant:
sufficient resources.
Transition from full
redundant state.
Degraded
04 – Non-redundant:
sufficient resources.
Transition from
insufficient state.
Degraded
05 - Non-redundant:
insufficient resources
Fatal