background image

San Telequip (P) Ltd., 
504/505 Deron Heights, Baner Road, Baner 
Pune 411045, Mah, India 
Phone    : +91-20-65001587, 9764027070, 8390069393                  Connecting. Converting. Leading! 
email    : 

[email protected]

                                                                                                                                                                                                                               

 

   

 

 

 

 

SC10E4IG_L   

Isolated 4 Port Device Server 

User’s Manual V1.0 

Summary of Contents for SC10E4IG_L

Page 1: ...504 505 Deron Heights Baner Road Baner Pune 411045 Mah India Phone 91 20 65001587 9764027070 8390069393 Connecting Converting Leading email info santelequip com SC10E4IG_L Isolated 4 Port Device Server User s Manual V1 0 ...

Page 2: ...ical Specification 4 Chapter 2 Hardware Instructions 6 2 1 Panel Layout 6 2 2 Connecting the Hardware 8 Chapter 3 Software Instructions 10 3 1 Virtual Serial port Software Installation 10 3 2 Virtual Serial port Software Description 12 3 3 Device Manager Software Introduction 17 3 4 WEB Network Management Profile 20 3 5 Telnet and Console Configuration Command 32 Chapter 4 LCD Optional Instruction...

Page 3: ...lst every effort has been made to ensure the accuracy and reliability of the contents contained herein the Company cannot be held liable for any harm or damage resulting from any omissions inaccuracies or errors contained in the manual Brief Introduction Thank you for choosing our products This User Manual describes the SC10E4IG Series Serial Device Server Before you use our device for the first t...

Page 4: ... Access control and Remote site management The Serial Data transfer is transparent serial data to Ethernet 1 2 Product Feature 4 of RS485 RS422 DIP selectable Connector is a 5 pin Terminal Block The serial baud rate supports 300bps to 115200bps Data access modes including TCP Server TCP Client UDP and Virtual COM Versatile socket operating modes including TCP Server TCP Client UDP and Virtual COM ...

Page 5: ...Line Protection EN 61000 4 2 ESD Level 3 EN 61000 4 5 Surge Level 3 Number of Optical Ports 1 Speed 100 Mbps Connector SFP Serial Interface Serial Standards RS485 RS422 DIP switch selectable Number of Ports 4 Type of Connectors 3 81mm double layer 5 Pin terminal block EMS EN 61000 4 2 ESD Level 4 EN 61000 4 5 Surge Level 3 EN 61000 4 5 Lightning Level 3 EN 61000 4 4 EFT Level 3 Port Isolation Seri...

Page 6: ...Telnet Configuration Options Web Windows Search Utility SNMP Telnet Windows Virtual COM Drivers Win7 Win8 Win2008 Server Win2012 Server Operation Modes Standard Virtual COM TCP Server TCP Client UDP Physical Characteristics Housing Metal Weight SC10E4IG_L 0 55kg Dimensions 40 5 W x 143 D x 210 H mm Environmental Limits Operating Temperature 0 to 50 C Storage Temperature 20 to 85 C Ambient Relative...

Page 7: ...onnecting Converting Leading email info santelequip com 6 Chapter 2 Hardware Instructions This chapter covers the hardware installation The following topics are covered in this chapter Panel Layout Connecting the Hardware Wiring Requirements Connecting to a Serial Device LED Indicators 2 1 Panel Layout SC10E4IG_L Front Panel ...

Page 8: ...r switches are OFF COM4 Switch 4 ON other switches are OFF Switch 7 8 ON other switches are OFF RS485 4 Wire COM1 Switch 1 ON other switches are OFF Switch 1 2 OFF other switches are ON COM2 Switch 2 ON other switches are OFF Switch 3 4 OFF other switches are ON COM3 Switch 3 ON other switches are OFF Switch 5 6 OFF other switches are ON COM4 Switch 4 ON other switches are OFF Switch 7 8 OFF other...

Page 9: ...ower before installing and wiring Disconnect the power cord before installing and or wiring your SC10E4IG Do not exceed the maximum current for the wiring Determine the maximum possible current for each power wire and common wire Observe all electrical codes dictating the maximum current allowable for each wire size If the current exceeds the maximum rating the wiring could overheat causing seriou...

Page 10: ...D Color LED Function PWR Green On Unit is powered Off Unit is off SYS Yellow Blinking System is working normally Off System is abnormal TX1 4 Green Blinking Data being sent Off No data being sent RX1 4 Green Blinking Data being received Off No data being received RJ45 Green On 100M Off 10M Orange Blinking Data on RJ45 is being transmitted On Eth port is connected Off Eth port is disconnected ACT G...

Page 11: ...opics are covered in this chapter Virtual Serial port Software Installation and Description Device Manager Software Installation and Description Web Manager Instructions 3 1 Virtual Serial port Software Installation Users should follow these steps to install the application on a computer of the Windows platform Step 1 Double click to run installation program VcomSetupV2 74e_no_tools exe Step 2 Cli...

Page 12: ...r Road Baner Pune 411045 Mah India Phone 91 20 65001587 9764027070 8390069393 Connecting Converting Leading email info santelequip com 11 Step 3 Click Install to start the installation process The installation will take some time please be patient ...

Page 13: ...9393 Connecting Converting Leading email info santelequip com 12 Step 4 Click Finish to complete the installation process 3 2 Virtual Serial port Software Description Virtual serial port software is used to simulate the serial port of the field devices on the computer Virtual serial port software show ports as follows ...

Page 14: ...k the icon to add serial ports a dialog box will pop up According to the Operating mode selected it will show corresponding dialog box as follows Parameter Description Serial Synch This device does not support synchronization Always keep it DISABLE VCom ID Start Select starting virtual serial port COM2 to COM512 VCom Count The no s of Ports that can be configured as VCOM ports This device supports...

Page 15: ... device can disconnect automatically Remote IP Enter the IP address of the Ethernet device connected to our Unit Port 1 Enter the Port number of the Ethernet device connected to our Unit The below table explains the relationship of the IP Address Port no in the Server and PC Computer Virtual serial port configuration Assume Computer s IP address IP A Port Port A Device Configuration Assume Device ...

Page 16: ...rt A Device Configuration Assume Device IP address IP B Port Port B Operating Mode TCP Client Device IP IP B Device Port Port B LAN Mode status TCP server Listening Port Port B Remote IP NA Port 1 NA VcomServerV2 74e SC10E4IG_L Page UDP mode Compared to TCP communication UDP is faster and more efficient In UDP mode you can Uni cast or Multi cast data from the serial device server to host computers...

Page 17: ...ress IP B Port Port B Operating Mode UDP Local Port Port A Device IP IP B Device Port Port B LAN Mode status UDP Listening Port Port B Remote IP IP A Port 1 Port A VcomServerV2 74e SC10E4IG_L Deleting a Virtual serial port Select the corresponding virtual serial port click the icon to delete Modify the Virtual serial port Select the corresponding virtual serial port click the icon to edit NOTE Mak...

Page 18: ...ly configure and maintain multiple Serial Devices It can search all the device check and configure network parameter and serial port parameter of device It also can remote update and reset device Firstly open the Device Manager you can select related button or menu to use each function Searching Device Through press Local Search button to update all Serial Device that are connected to the same LAN...

Page 19: ...070 8390069393 Connecting Converting Leading email info santelequip com 18 Setting To modify the configuration of a particular Serial Device first select the device entry and then select Setting icon or click on the Setting under the Setting menu Press System Information can check the device Model MAC address ...

Page 20: ... Pune 411045 Mah India Phone 91 20 65001587 9764027070 8390069393 Connecting Converting Leading email info santelequip com 19 Press Network to show the device IP address Submask and Gateway The COM Parameters page is used to modify the settings of Serial Port ...

Page 21: ...meets any of the 2 conditions Min Send Time or Min Send Size it will send the data to the network If serial port is at low baud rate we suggest to change the Min Send Size to smaller value 3 4 WEB Network Management Profile 3 4 1 Using Your Web Browser Open your browser enter the device IP and then enter the user name and password as the following steps Default IP IP address 192 168 0 100 User nam...

Page 22: ... 9764027070 8390069393 Connecting Converting Leading email info santelequip com 21 Note The Settings will be saved to the configuration file Network Config This page is to set the Device IP Subnet Mask Gateway MAC Address DHCP LAN Mode Redundancy Mode or Switch Mode DNS Server details Redundancy Mode ...

Page 23: ... Master When LAN 1 cable is removed then pinging starts after 2 3 sec in LAN2 but when LAN1 is connected again LAN2 stop pinging LAN1 start pinging At a time one LAN port works Switch Mode Both LAN ports work at a time Note Once the IP address changes please enter the new address in your browser System reboot Reboot the device or restore factory settings Note If Restore factory setting is selected...

Page 24: ...23 System Upgrade Upgrade Tips Step 1 Upload the upgrade file Step 2 Choose upgrade software or configuration file to upgrade Change Password This page can change the Password Note The password length should not be less than 5 digits Ethernet Port Configuration This page is to set the Ethernet Port to 10M HALF Duplex 10M FULL Duplex 100M HALF Duplex 100M FULL Duplex or Auto Mode ...

Page 25: ...ne 91 20 65001587 9764027070 8390069393 Connecting Converting Leading email info santelequip com 24 VLAN Config VLAN Enable Configure This page is to set VLAN Enable QinQ Enable QinQ Type QinQ PVID and Upstream port selection VLAN List Configure This page is to set the VLAN List table ...

Page 26: ...ecting Converting Leading email info santelequip com 25 PVID Configure This page is to set the Ethernet Port PVID Configure Serial Config Serial port Config This page is to set single Serial port parameters select the Serial No and then enter the details Template Application This page is to set a batch of Serial port parameters ...

Page 27: ...87 9764027070 8390069393 Connecting Converting Leading email info santelequip com 26 Serial Information Display the current status information of all the Serial ports Serial Statistics Check the detailed communication performance of each Serial port Note The statistics data refreshes every 5 seconds ...

Page 28: ...ould be valid Check with your System Admin 2 Your System is Internet enabled else you will not receive emails 3 Your email id is working properly and can receive transmit emails Confirm that your system admin has not blocked this domain 4 Check the User Name Password of the email independently 5 The User name password to be filled in the below screen should be that of the Sender email id holder 6 ...

Page 29: ...tatus Event Mail Received Alarm Event Set the Alarms for Login Failed Port Connected Port Disconnected Password Changed Lan Status and the SNMP Trap Server IP You can choose out of the 5 Alerts available in our device You can also choose the Alarm type as Traps or Emails or Both You will have to load a MIB Browser on a PC to see the Traps generated The IP address of this PC should be entered as SN...

Page 30: ...elequip P Ltd 504 505 Deron Heights Baner Road Baner Pune 411045 Mah India Phone 91 20 65001587 9764027070 8390069393 Connecting Converting Leading email info santelequip com 29 Trap received in MIB Browser ...

Page 31: ...YSLOG too You can choose to Set the Syslog to give you information on Login Failed IP Changed Password Changed and Lan Status You can view the Syslog history and also clear it on this window Password change LAN Status log received in Syslog WEB configuration page does not open in normal condition but when Connect to internet then WEB page is getting open If Internet Explorer Proxy Server option is...

Page 32: ...ts Baner Road Baner Pune 411045 Mah India Phone 91 20 65001587 9764027070 8390069393 Connecting Converting Leading email info santelequip com 31 1 In Internet Explorer browser selects Tools Internet options 2 Select Connections LAN settings ...

Page 33: ...il info santelequip com 32 3 Proxy Server option is selected IP address use of the SC10E4IG 4 Enter SC10E4IG_L IP address in Internet Explorer browser then enter User name and password are both admin 5 SC10E4IG_L WEB configuration page is open 3 5 Telnet and Console Configuration Command 1 User name and Password The default user and password are both root ...

Page 34: ...er Pune 411045 Mah India Phone 91 20 65001587 9764027070 8390069393 Connecting Converting Leading email info santelequip com 33 1 1 Enter the screen displays as follows 1 2 Enter help displays as follows 1 3 Enter show sys_conf to show the system configure ...

Page 35: ...ner Road Baner Pune 411045 Mah India Phone 91 20 65001587 9764027070 8390069393 Connecting Converting Leading email info santelequip com 34 1 4 Enter show net_conf to show the network configure 1 5 Enter show port_conf to show all port configure ...

Page 36: ... Road Baner Pune 411045 Mah India Phone 91 20 65001587 9764027070 8390069393 Connecting Converting Leading email info santelequip com 35 1 6 Enter show email_conf to show all email configure 2 Enter the privileged commands enable 2 1 Input help or ...

Page 37: ...il info santelequip com 36 2 2 Enter sh Call linux shell Enter the Linux interface like the previous version of the console this is for our internal support 2 3 timeout Set timeout interval For example Input timeout 30 which means that you cannot operate the system untill the 30 seconds expires 3 Configuration Interface config Enter configure then or help ...

Page 38: ...h India Phone 91 20 65001587 9764027070 8390069393 Connecting Converting Leading email info santelequip com 37 3 1 Network Information Settings page Enter network then or help Usage ipaddr xxx xxx xxx xxx Usage mask xxx xxx xxx xxx Usage gateway xxx xxx xxx xxx For example ...

Page 39: ...45 Mah India Phone 91 20 65001587 9764027070 8390069393 Connecting Converting Leading email info santelequip com 38 3 2 System Information Settings page Enter system then or help Usage name data Usage description data Usage location data Usage contact data For example ...

Page 40: ...0069393 Connecting Converting Leading email info santelequip com 39 The device name is changed to SAN_TECH The default configuration is corresponding to the web page 3 3 Port Information Settings page Enter port then or help All the serial port Baud rate setting Usage bdr b9600 All the serial port work mode setting ...

Page 41: ...505 Deron Heights Baner Road Baner Pune 411045 Mah India Phone 91 20 65001587 9764027070 8390069393 Connecting Converting Leading email info santelequip com 40 Single serial port setting Input port x For example then or help ...

Page 42: ...D Optional Instructions 4 1 The Key Function MENU return to the previous menu SEL enter the submenu In the specific parameter setting it functions as confirm UP DOWN used for upward downward scrolling In the IP configuration interface press SEL to enter the editing interface or move the cursor Note The font and cursor on the LCD screen are both black 4 2 The Menu Structure LAN UP 192 168 0 100 ...

Page 43: ...069393 Connecting Converting Leading email info santelequip com 42 4 3 Detailed Description 4 3 1 Welcome Screen After Power on the LCD shows status and IP of LAN The display format is given as follows Input the default password 1234 Press to enter the main menu 4 3 2 Main Menu Structure LAN Link DOWN 192 168 000 100 ...

Page 44: ...ading email info santelequip com 43 4 3 3 Overview The yellow highlighted 1 above will blink actual blinking in black and white Press to return to previous menu to enter the submenu and to switch between the different layers If the cursor is blinking you can enter the submenu or input the editing content Working is displayed in a Simple flow chart ...

Page 45: ...n the cursor is blinking you can enter the submenu or input the editing content Note 2 means press two times 1 press once Steps to modify IP In operate as above to enter Then press to enter editing mode the cursor will blink in the position of 1 Press to move back the cursor Press or to modify IP In this mode you can press to exit If the data IP is changed the following interface will display Then...

Page 46: ... interface or move the cursor by pressing SEL Pressing MENU to exit the edit mode or return to previous menu 4 3 5 Serial Settings This option is to set the serial port After entering this menu four submenus are available SELECT PORT Select Mode Parameter Set Link Mode Before each configuration you d better access the SELECT PORT interface to confirm the current port in case is set Select Mode Par...

Page 47: ...nterface will display Then operate according to the screen prompts If the port number is not changed it will exit the editing interface without displaying the above content Since configuration of other parameters are similar no need to repeat here During the configuration of other parameters the screen may display which asks whether to apply the configuration to all ports or not The operation is s...

Page 48: ...ing Leading email info santelequip com 47 Note The green border interface means that pressing SEL can enter the submenu In the IP configuration interface you can enter the editing interface or move the cursor by pressing SEL Pressing MENU to exit the edit status or return to previous menu 4 3 6 Server State Simple flow chart works as follows ...

Page 49: ...key distribution The Modification of LAN PING IP refer to 4 3 4 Network Settings EXEC PING refer to section 4 3 5 APPLY TO ALL or 4 3 7 Restart As the functional is similar to LAN PING so here we only illustrate the operation of LAN 4 3 7 Restart In this page press to enter the select status Press or to switch between NO and YES If the cursor is blinking press to select operation Press to exit or ...

Reviews: