Intel® Server Board S2600CW Connector/Header Locations and Pin-outs
Intel® Server Board S2600CW Family TPS
104
Revision 2.4
Table 27. RMM4 Lite Connector Pin-out
Pin
Signal Name
Pin
Signal Name
1
P3V3_AUX
2
DI
3
KEY
4
CLK
5
DO
6
GND
7
CS_N
8
GND
7.4.2
TPM Connector
Table 28. TPM Connector Pin-out
Pin
Signal Name
Pin
Signal Name
1
Key
2
LPC_LAD<1>
3
LPC_LAD<0>
4
GND
5
IRQ_SERIAL
6
LPC_FRAME_N
7
P3V3
8
GND
9
RST_IBMC_NIC_N_R2
10
CLK_33M_TPM
11
LPC_LAD<3>
12
GND
13
GND
14
LPC_LAD<2>
7.4.3
PMBus* Connector
Table 29. PMBus* Connector Pin-out
Pin
Signal Name
1
SMB_PMBUS_CLK_R
2
SMB_PMBUS_DATA_R
3
IRQ_SML1_PMBUS_ALERT_RC_N
4
GND
5
P3V3
7.4.4
Chassis Intrusion Header
The server board includes a 2-pin chassis intrusion header which can be used when the
chassis is configured with a chassis intrusion switch. The header has the following pin-out.
Table 30. Chassis Intrusion Header Pin-out
Header State
Description
Pins 1 and 2 closed
FM_INTRUDER_HDR_N is pulled HIGH. Chassis cover is closed.
Pins 1 and 2 open
FM_INTRUDER_HDR_N is pulled LOW. Chassis cover is removed.