Intel® Server Board S2600CW Family TPS
Intel® Server Board S2600CW Connector/Header Locations and Pin-outs
Revision 2.4
101
Pin
Signal Name
Pin
Signal Name
1D1
PU_DATAIN1_SAS1
2D1 PU_DATAIN1_SAS0
1A2
SGPIO_SSATA_CLOCK_R1
2A2
SGPIO_SATA_CLOCK_R1
1B2
SGPIO_SSATA_LOAD_R1
2B2
SGPIO_SATA_LOAD_R1
1C2
GND
2C2
GND
1D2
PD_SAS1_CONTROLLER_TYPE
2D2 PD_SAS0_CONTROLLER_TYPE
7.3.2
SAS Connectors
The server boards S2600CW2SR and S2600CWTSR include two mini-SAS HD connectors
supporting up to SAS 12Gbps transfer rates. The following table provides the pin-out for each
connector.
Table 21. Mini-SAS HD Connectors for SAS 12Gbps Pin-out
Pin
Signal Name
Pin
Signal Name
1A1
TP_SAS1_BACKPLANE_TYPE
2A1
TP_SAS0_BACKPLANE_TYPE
1B1
GND
2B1
GND
1C1
SGPIO_SSATA_DATAOUT0_R1
2C1
SGPIO_SATA_DATAOUT0_R1
1D1
SGPIO_DATAIN
2D1 SGPIO_DATAIN
1A2
SGPIO_SSATA_CLOCK_R1
2A2
SGPIO_SATA_CLOCK_R1
1B2
SGPIO_SSATA_LOAD_R1
2B2
SGPIO_SATA_LOAD_R1
1C2
GND
2C2
GND
1D2
PD_SAS1_CONTROLLER_TYPE
2D2 PD_SAS0_CONTROLLER_TYPE
7.3.3
HSBP I
2
C Header
Table 22. HSBP I
2
C Header Pin-out
Pin
Signal Name
1
SMB_HSBP_3V3STBY_DATA
2
GND
3
SMB_HSBP_3V3STBY_CLK
7.3.4
HDD LED Header
The server board includes a 2-pin hard drive activity LED header used with some SAS/SATA
controller add-in cards. The header has the following pin-out.