Intel® Server Board S2600CW Jumper Blocks
Intel® Server Board S2600CW Family TPS
114
Revision 2.4
6.
Perform the Integrated BMC firmware update procedure as documented in the
README.TXT file that is included in the given Integrated BMC firmware update package.
After successful completion of the firmware update process, the firmware update utility
may generate an error stating that the Integrated BMC is still in update mode.
7.
Power down and remove the AC power cord.
8.
Open the server chassis.
9.
Move jumper from the enabled position (covering pins 2 and 3) to the disabled position
(covering pins 1 and 2).
10.
Close the server chassis.
11.
Reconnect the AC cord and power up the server.
Note
: Normal Integrated BMC functionality is disabled with the Force Integrated BMC Update
jumper set to the enabled position. The server should never be run with the Integrated BMC
Force Update jumper set in this position. This jumper setting should only be used when the
standard firmware update process fails. This jumper should remain in the default/disabled
position when the server is running normally.
8.3
ME Force Update Jumper
When the ME Firmware Force Update jumper is moved from its default position, the ME is
forced to operate in a reduced minimal operating capacity. This jumper should only be used if
the ME firmware has gotten corrupted and requires re-installation. The following procedure
should be followed.
1.
Power down and remove the AC power cord.
2.
Open the server chassis. For instructions, see your server chassis documentation.
3.
Move jumper from the default operating position (covering pins 1 and 2) to the enabled
position (covering pins 2 and 3).
4.
Close the server chassis.
5.
Reconnect the AC cord and power up the server.
6.
Boot to the EFI shell and update the ME firmware using the “MEComplete.cap” file using
the following command:
iflash32 /u /ni MEComplete.cap
7.
Power down and remove the AC power cord.
8.
Open the server chassis.
9.
Move jumper from the enabled position (covering pins 2 and 3) to the disabled position
(covering pins 1 and 2).
10.
Close the server chassis.
11.
Reconnect the AC cord and power up the server.