Appendix C: BMC Sensor Tables
Intel® Server Board S2600CW Family TPS
166
Revision 2.4
Full Sensor Name
(Sensor name in SDR)
Senso
r #
Platform
Applicabili
ty
Sensor Type
Event/Rea
ding Type
Event Offset
Triggers
Contrib. To
System
Status
Assert
/De-
assert
Readab
le
Value/
Offsets
Event
Data
Rearm Stand-
by
Power Supply 2 Fan
Tachometer 2
(PS2 Fan Tach 2)
A5h
Chassis-
specific
Fan
04h
Generic –
digital
discrete
03h
01 – State Asserted
Non-fatal
As
and
De
-
Trig Offset
M
-
MIC 3 Status
(GPGPU3 Status)
A6h
Platform
Specific
Status
C0h
OEM
Defined
70h
-
-
-
-
-
-
-
MIC 4 Status
(GPGPU4 Status)
A7h
Platform
Specific
Status
C0h
OEM
Defined
70h
-
-
-
-
-
-
-
Processor 1 DIMM Aggregate
Thermal Margin 1
(P1 DIMM Thrm Mrgn1)
B0h
All
Temperature
01h
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-fatal
As
and
De
Analog
R, T
A
–
Processor 1 DIMM Aggregate
Thermal Margin 2
(P1 DIMM Thrm Mrgn2)
B1h
All
Temperature
01h
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-fatal
As
and
De
Analog
R, T
A
–
Processor 2 DIMM Aggregate
Thermal Margin 1
(P2 DIMM Thrm Mrgn1)
B2h
All
Temperature
01h
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-fatal
As
and
De
Analog
R, T
A
–
Processor 2 DIMM Aggregate
Thermal Margin 2
(P2 DIMM Thrm Mrgn2)
B3h
All
Temperature
01h
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-fatal
As
and
De
Analog
R, T
A
–
Processor 3 DIMM Aggregate
Thermal Margin 1
(P3 DIMM Thrm Mrgn1)
B4h
Platform
Specific
Temperature
01h
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-fatal
As
and
De
Analog
R, T
A
–
Processor 3 DIMM Aggregate
Thermal Margin 2
(P3 DIMM Thrm Mrgn2)
B5h
Platform
Specific
Temperature
01h
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-fatal
As
and
De
Analog
R, T
A
–