Appendix C: BMC Sensor Tables
Intel® Server Board S2600CW Family TPS
162
Revision 2.4
Full Sensor Name
(Sensor name in SDR)
Senso
r #
Platform
Applicabili
ty
Sensor Type
Event/Rea
ding Type
Event Offset
Triggers
Contrib. To
System
Status
Assert
/De-
assert
Readab
le
Value/
Offsets
Event
Data
Rearm Stand-
by
06 – Configuration
error
OK
Power Supply 2 Status
Note2
(PS2 Status)
51h
Chassis-
specific
Power Supply
08h
Sensor
Specific
6Fh
00 - Presence
OK
As
and
De
–
Trig Offset
A
X
01 - Failure
Degraded
02 – Predictive Failure
Degraded
03 - A/C lost
Degraded
06 – Configuration
error
OK
Power Supply 1
AC Power Input
(PS1 Power In)
54h
Chassis-
specific
Other Units
0Bh
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-fatal
As
and
De
Analog
R, T
A
X
Power Supply 2
AC Power Input
(PS2 Power In)
55h
Chassis-
specific
Other Units
0Bh
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-fatal
As
and
De
Analog
R, T
A
X
Power Supply 1 +12V % of
Maximum Current Output
(PS1 Curr Out %)
58h
Chassis-
specific
Current
03h
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-fatal
As
and
De
Analog
R, T
A
X
Power Supply 2 +12V % of
Maximum Current Output
(PS2 Curr Out %)
59h
Chassis-
specific
Current
03h
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-fatal
As
and
De
Analog
R, T
A
X
Power Supply 1 Temperature
(PS1 Temperature)
5Ch
Chassis-
specific
Temperature
01h
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-fatal
As
and
De
Analog
R, T
A
X
Power Supply 2 Temperature
(PS2 Temperature)
5Dh
Chassis-
specific
Temperature
01h
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-fatal
As
and
De
Analog
R, T
A
X
Hard Disk Drive 15 - 23
Status
60h
–
Chassis-
specific
Drive Slot
0Dh
Sensor
Specific
00 - Drive Presence
OK
As
and
–
Trig Offset
A
X
X
01- Drive Fault
Degraded