Intel® Server Board S2600CW Family TPS
Appendix D: Platform Specific BMC Appendix
Revision 2.4
173
Chassis
Fan Domain
Major Components Cooled
(Temperature sensor number)
Fans
(Sensor number)
P2 DTS Therm Mgn (84h)
MIC 1 Margin (C4h)
MIC 2 Margin (C5h)
MIC 3 Margin (C6h)
1
DIMM Thrm Mrgn 1 (B0h)
DIMM Thrm Mrgn 2 (B1h)
DIMM Thrm Mrgn 3 (B2h)
DIMM Thrm Mrgn 4 (B3h)
LAN/BMC Temp (23h)
HSBP 1 Temp (29h)
SSB Temp (22h)
LAN NIC Temp (2Fh)
Exit Air Temp (2Eh)
P1 DTS Therm Mgn (83h)
P2 DTS Therm Mgn (84h)
MIC 1 Margin (C4h)
MIC 2 Margin (C5h)
MIC 3 Margin (C6h)
System Fan 2 (31h)
2
DIMM Thrm Mrgn 1 (B0h)
DIMM Thrm Mrgn 2 (B1h)
DIMM Thrm Mrgn 3 (B2h)
DIMM Thrm Mrgn 4 (B3h)
SAS IOC Temp (D6h)
MEM EFVRD Temp (24h)
MEM VRM Temp (D5h)
P1 VRD Temp (25h)
HSBP 1 Temp (29h)
Exit Air Temp (2Eh)
P1 DTS Therm Mgn (83h)
P2 DTS Therm Mgn (84h)
MIC 1 Margin (C4h)
MIC 2 Margin (C5h)
MIC 3 Margin (C6h)
System Fan 3 (32h)
3
DIMM Thrm Mrgn 1 (B0h)
DIMM Thrm Mrgn 2 (B1h)
DIMM Thrm Mrgn 3 (B2h)
DIMM Thrm Mrgn 4 (B3h)
SAS IOC Temp (D6h)
MEM EFVRD Temp (24h)
MEM VRM Temp (D5h)
P1 VRD Temp (25h)
HSBP 1 Temp (29h)
System Fan 4 (33h)