Intel® Server Board S2600CW Family TPS
Appendix C: BMC Sensor Tables
Revision 2.4
163
Full Sensor Name
(Sensor name in SDR)
Senso
r #
Platform
Applicabili
ty
Sensor Type
Event/Rea
ding Type
Event Offset
Triggers
Contrib. To
System
Status
Assert
/De-
assert
Readab
le
Value/
Offsets
Event
Data
Rearm Stand-
by
(HDD 15 - 23 Status)
68h
6Fh
07 - Rebuild/Remap
in progress
Degraded
De
Processor 1 Status
(P1 Status)
70h
All
Processor
07h
Sensor
Specific
6Fh
01 - Thermal trip
Fatal
As
and
De
–
Trig Offset
M
X
07 - Presence
OK
Processor 2 Status
(P2 Status)
71h
All
Processor
07h
Sensor
Specific
6Fh
01 - Thermal trip
Fatal
As
and
De
–
Trig Offset
M
X
07 - Presence
OK
Processor 3 Status
(P3 Status)
72h
Platform-
specific
Processor
07h
Sensor
Specific
6Fh
01 - Thermal trip
Fatal
As
and
De
–
Trig Offset
M
X
07 - Presence
OK
Processor 4 Status
(P4 Status)
73h
Platform-
specific
Processor
07h
Sensor
Specific
6Fh
01 - Thermal trip
Fatal
As
and
De
–
Trig Offset
M
X
07 - Presence
OK
Processor 1 Thermal Margin
(P1 Therm Margin)
74h
All
Temperature
01h
Threshold
01h
-
-
-
Analog
R, T
A
–
Processor 2 Thermal Margin
(P2 Therm Margin)
75h
All
Temperature
01h
Threshold
01h
-
-
-
Analog
R, T
A
–
Processor 3 Thermal Margin
(P3 Therm Margin)
76h
Platform-
specific
Temperature
01h
Threshold
01h
-
-
-
Analog
R, T
A
–
Processor 4 Thermal Margin
(P4 Therm Margin)
77h
Platform-
specific
Temperature
01h
Threshold
01h
-
-
-
Analog
R, T
A
–
Processor 1 Thermal
Control %
(P1 Therm Ctrl %)
78h
All
Temperature
01h
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-fatal
As
and
De
Analog
Trig Offset
A
–
Processor 2 Thermal
Control %
(
P2 Therm Ctrl %
)
79h
All
Temperature
01h
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-fatal
As
and
De
Analog
Trig Offset
A
–