Intel® Server Board S2600CW Family TPS
Appendix C: BMC Sensor Tables
Revision 2.4
165
Full Sensor Name
(Sensor name in SDR)
Senso
r #
Platform
Applicabili
ty
Sensor Type
Event/Rea
ding Type
Event Offset
Triggers
Contrib. To
System
Status
Assert
/De-
assert
Readab
le
Value/
Offsets
Event
Data
Rearm Stand-
by
Processor 4 DTS Thermal
Margin
(P4 DTS Therm Mgn)
86h
Platform
Specific
Temperature
01h
Threshold
01h
-
-
-
Analog
R, T
A
–
Auto Config Status
(AutoCfg Status)
87h
All
Mgmt Health
28h
Digital
Discrete
03h
01 – State Asserted
-
As
and
De
–
Trig Offset
A
-
VRD Over Temperature
(
VRD Hot
)
90h
All
Temperature
01h
Digital
Discrete
05h
01 - Limit exceeded
Non-fatal
As
and
De
–
Trig Offset
A
–
Power Supply 1 Fan
Tachometer 1
(PS1 Fan Tach 1)
A0h
Chassis-
specific
Fan
04h
Generic –
digital
discrete
03h
01 – State Asserted
Non-fatal
As
and
De
-
Trig Offset
M
-
Power Supply 1 Fan
Tachometer 2
(PS1 Fan Tach 2)
A1h
Chassis-
specific
Fan
04h
Generic –
digital
discrete
03h
01 – State Asserted
Non-fatal
As
and
De
-
Trig Offset
M
-
MIC 1 Status
(GPGPU1 Status)
A2h
Platform
Specific
Status
C0h
OEM
Defined
70h
-
-
-
-
-
-
-
MIC 2 Status
(GPGPU2 Status)
A3h
Platform
Specific
Status
C0h
OEM
Defined
70h
-
-
-
-
-
-
-
Power Supply 2 Fan
Tachometer 1
(PS2 Fan Tach 1)
A4h
Chassis-
specific
Fan
04h
Generic –
digital
discrete
03h
01 – State Asserted
Non-fatal
As
and
De
-
Trig Offset
M
-