149/160
AB Industrietechnik srl – Via Julius Durst, 70 – 39042 BRESSANONE (BZ) Italy – Tel: +39 0472/830626 – [email protected] – www.industrietechnik.it
Register Description
Default
Min
Max
R/W
9163
PROP_BAND_REG_HEAT
→
Heating proportional band
(Δ°C [Δ°F])
(Note1)
114
20 [36]
10 [18]
200 [360]
R/W
9164
INTEGRAL_TIME_REG_HEAT
→
Heating integral time (s)
115
0
0
999
R/W
9165
PROP_BAND_REG_COOL
→
Cooling proportional band
(Δ°C [Δ°F])
(Note1)
116
20 [36]
10 [18]
200 [360]
R/W
9166
INTEGRAL_TIME_REG_COOL
→
Cooling integral time (s)
117
0
0
999
R/W
9167
PROP_BAND_SUPPLY
→
Proportional band for the calculation of the
supply setpoint in cascade control
(Δ°C [Δ°F])
(Note1)
118
200 [360]
10 [18]
500 [900]
R/W
9168
INTEGRAL_TIME_SUPPLY
→
Integral time for calculation of supply
setpoint in cascade control (s)
119
0
0
999
R/W
9169
ECO_SET_ADJUST
→
Economy or boost offset
(Δ°C [Δ°F])
(Note1)
120
30 [5]
-120 [-22]
120 [22]
R/W
9170
HOL_SET_ADJUST
→
Offset mode for “non-occupied/holiday” operation
(Δ°C [Δ°F])
(Note1)
121
50 [9]
10 [2]
140 [25]
R/W
9171
DO_HYST
→
Hysteresis for on/off output
(Δ°C [Δ°F])
(Note1)
122
10 [18]
5 [10]
20 [36]
R/W
9172
DEAD_ZONE
→
Neutral zone for 4-pipe systems
(Δ°C [Δ°F])
(Note1)
123
10 [18]
5 [10]
50 [90]
R/W
9173
DIFF_INSERT_HEATING
→
Differential addition of heating in summer
season (mid-season)
(Δ°C [Δ°F])
(Note1)
124
30 [54]
5 [10]
100 [180]
R/W
9174
AUTHORIZE_LIM_SUPPLY_LOW
→
Activation of minimum supply limit for
fixed-point control
0=not enabled
1=enabled in cooling mode
2=enabled in heating mode
3=enabled in heating and cooling modes
125
0
0
3
R/W
9175
SET_LIM_LOW
→
Minimum low supply limit setpoint (°C [°F])
(Note1)
126
100 [50]
60 [43]
128
R/W
9176
AUTHORIZE_LIM_SUPPLY_HIGH
→
Activation of maximum supply limit for
fixed-point control
0=not enabled
1=enabled in cooling mode
2=enabled in heating mode
3=enabled in heating and cooling modes
127
0
0
3
R/W
9177
SET_LIM_HIGH
→
High supply limit setpoint
(°C [°F])
(Note1)
128
400 [86]
126
500 [122]
R/W
9178
PROP_BAND_LIM
→
Proportional band for the limit (Δ°C [Δ°F])
(Note1)
129
20 [36]
10 [18]
200 [360]
R/W
9179
AUTHORIZE_SETPOINT_COMPENSATION
→
Activation of compensation
for operations with
014
=1 or 4
0=not enabled
1=enabled in cooling mode
2=enabled in heating mode
3=enabled in heating and cooling modes
130
0
0
3
R/W
9180
TEMP_EXT_MIN_COMP_HEATING
→
Minimum external temperature for
winter compensation (°C [°F])
(Note1)
131
-100 [14]
-100 [14]
I32
R/W
9181
TEMP_EXT_MAX_COMP_HEATING
→
Maximum external temperature for
winter compensation (°C [°F])
(Note1)
132
200 [68]
I31
50.0 [122]
R/W
9182
SET_TEXT_MIN_COMP_HEATING
→
Compensation setpoint
corresponding to the minimum external temperature for winter
compensation (°C [°F])
(Note1)
133
600 [140]
50 [41]
800 [176]
R/W
9183
SET_TEXT_MAX_COMP_HEATING
→
Compensation setpoint
corresponding to the maximum external temperature for winter
compensation
(°C [°F])
(Note1)
134
300 [86]
50 [41]
800 [176]
R/W
9184
TEMP_EXT_MIN_COMP_COOLING
→
Minimum external temperature for
summer compensation (°C [°F])
(Note1)
135
220 [72]
-100 [14]
I36
R/W
9185
TEMP_EXT_MAX_COMP_COOLING
→
Maximum external temperature for
summer compensation (°C [°F])
(Note1)
136
350 [95]
I35
500 [122]
R/W
9186
SET_TEXT_MIN_COMP_COOLING
→
Compensation setpoint
corresponding to the minimum external temperature for summer
compensation (°C [°F])
(Note1)
137
190 [66]
50 [41]
800 [176]
R/W
9187
SET_TEXT_MAX_COMP_COOLING
→
Compensation setpoint
corresponding to the maximum external temperature for summer
compensation
(°C [°F])
(Note1)
138
160 [61]
50 [41]
800 [176]
R/W
9188
AUTHORIZE_DEHUMIDIFICATION
→
Activation of dehumidification
0=not enabled
1=enabled with built-in humidity sensor
2=enabled with remote humidity sensor
3=enabled with built-in humidity sensor in cooling only
4=enabled with remote humidity sensor in cooling only
139
0
0
4
R/W
9189
AUTHORIZE_HUMIDIFICATION
→
Activation of humidification
0=not enabled
1=enabled with built-in humidity sensor
2=enabled with remote humidity sensor
140
0
0
2
R/W
9190
DEAD_ZONE_HUM
→
Neutral zone humidity
(Note2)
141
60
40
200
R/W