Register Description
Default
Min
Max
R/W
9146
ANALOG_OUTPUT1_FUNC
→
Analogue output operation 1 (models AHU-
4xxSx1 excluded)
0=not used
1=supply fan output
2=extraction fan output
3=heating valve output for 2/4-pipe appliances
4=cooling valve output for 2/4-pipe appliances
5=mixed-use valve output for 2-tube appliances
6=modulating electrical resistance output
7=post-heating valve output
8=post-heating electrical resistance output
9=modulating damper output
10=modulating humidifier
11=modulating dehumidifier
12=modulating rotary heat exchanger
13=modulating bypass damper for heat exchanger
030
0
0
13
R/W
9147
ANALOG_OUTPUT2_FUNC
→
Analogue output operation 2 (models AHU-
2xxSx1, AHU-4xxSx1 excluded)
0=not used
1=supply fan output
2=extraction fan output
3=heating valve output for 2/4-pipe appliances
4=cooling valve output for 2/4-pipe appliances
5=mixed-use valve output for 2-tube appliances
6=modulating electrical resistance output
7=post-heating valve output
8=post-heating electrical resistance output
9=modulating damper output
10=modulating humidifier
11=modulating dehumidifier
12=modulating rotary heat exchanger
13=modulating bypass damper for heat exchanger
031
0
0
13
R/W
9148
ANALOG_OUTPUT3_FUNC
→
Analogue output operation 3 (models AHU-
1xxSx1, AHU-2xxSx1, AHU-3xxSx1, AHU-4xxSx1 excluded)
0=not used
1=supply fan output
2=extraction fan output
3=heating valve output for 2/4-pipe appliances
4=cooling valve output for 2/4-pipe appliances
5=mixed-use valve output for 2-tube appliances
6=modulating electrical resistance output
7=post-heating valve output
8=post-heating electrical resistance output
9=modulating damper output
10=modulating humidifier
11=modulating dehumidifier
12=modulating rotary heat exchanger
13=modulating bypass damper for heat exchanger
032
0
0
13
R/W
9149
Reserved address
9150
COR_INT_TEMP
→
Correction of internal temperature
(Δ°C [Δ°F])
(Note1)
101
0
-50 [-90]
50 [90]
R/W
9151
COR_INT_HUM
→
Correction of internal humidity detected
(Note2)
102
0
-100
100
R/W
9152
COR_REM_AI1
→
Correction of temperature
AI1
(Δ°C [Δ°F])
(Note1)
103
0
-50 [-90]
50 [90]
R/W
9153
COR_REM_AI2
→
Correction of temperature
AI2
(Δ°C [Δ°F])
(Note1)
104
0
-50 [-90]
50 [90]
R/W
9154
COR_REM_AI3
→
Correction of temperature
AI3
(Δ°C [Δ°F])
(Note1)
105
0
-50 [-90]
50 [90]
R/W
9155
WEIGHT_REM_AIR
→
Weighting % of the remote control sensor in relation
to the internal sensor (if
019
=1 (AI1) or
021
=1 (AI2) or
023
=1 (AI3))
106
0
0
100
R/W
9156
BASIC_HEAT_SET
→
Heating setpoint for control without compensation
(°C [°F])
(Note1)
107
200 [68]
111
110
R/W
9157
BASIC_COOL_SET
→
Cooling setpoint for control without compensation
(°C [°F])
(Note1)
108
250 [77]
113
112
R/W
9158
BASIC_SET_4_PIPE
→
Setpoint for 4-pipe control without compensation
(°C [°F])
(Note1)
109
210 [70]
111
110
R/W
9159
DEV_SET_UPWARD_HEAT
→
Maximum heating control setpoint value
(°C
[°F])
(Nota1)
110
400 [104]
111
500 [122]
R/W
9160
DEV_SET_DOWNWARD_HEAT
→
Minimum heating control setpoint value
(°C [°F])
(Note1)
111
60 [43]
60 [43]
110
R/W
9161
DEV_SET_UPWARD_COOL
→
Maximum cooling control setpoint (°C [°F])
(Note1)
112
400 [104]
113
500 [122]
R/W
9162
DEV_SET_DOWNWARD_COOL
→
Minimum cooling control setpoint
(°C [°F])
(Note1)
113
60 [43]
60 [43]
112
R/W