Platinum™ IP3
Installation and Operation Manual
Alarm Expansion Module (PX-ALARM)
© 2016 Imagine Communications Corp.
Proprietary and Confidential.
September 2016 | Page 66
Status and Alarm LEDs
The PX-ALARM maintains standard reporting LEDs in addition to the status of alarms. All LEDs are visible
from the rear of the frame.
Table 22:
Status and Alarm LEDs
LED
Reference
Function
D1
GPO 1
Turns red when GPO output (condition defined by user is asserted true)
D2
GPO 2
D3
GPO 3
D4
GPO 4
D5
GPI Input 1
Turns red when GPI Input1 is asserted (contact closure to ground)
D6
GPI Input 2
Turns red when GPI input 2 is asserted (contact closure to ground)
D7
Power supply Alarm (PS ALM)
Turns red when any present power supply’s alarm is asserted/triggered.
D8
Fan Alarm (FAN ALM)
Turns red when any fans fail
D9
Control LED (CTRL)
Initializes red, turns green when communication with the Resource card (PX-
RES) is working.
D10
+24V Power Supply (+24V)
Turns green when either power is present from either Zone 1 or 2
D11
GPI Input 1
Turns red when GPI Input 3 is asserted (contact closure to ground)
There are LED indicators on the Resource Module and the Power Supply Modules
Status LEDs
indicate power supply status, resource module usage, and link light indicators for
Ethernet communication ports.
Alarm LEDs
indicate user defined alarm conditions.
LED indicators reflect the status of subsystems inside the frame. The indicators for each power supply
provide information on each voltage rail and the power supply’s fan. The indicators from each resource
module provide status information of the frame’s resource module. These indicators are lit green when
the system is functioning properly and red if a failure condition exists.
Failsafe Upgrade
Should the PX-ALARM module get corrupted and the Platinum IP3 Controller cannot update the
firmware:
Press and hold the
Fail Safe A
and
Fail Safe D
for 3 seconds.
Use a paper clip to Press the button on the back of the Alarm module.