Platinum™ IP3
Installation and Operation Manual
Output Modules (PX-OB)
© 2016 Imagine Communications Corp.
Proprietary and Confidential.
September 2016 | Page 123
Table 54:
Module System LEDs
LED
DESCRIPTION
OUTPUT 1-16
Signal Presence
Green
Signal Present
POWER
Power Supply indicator
Green
+24V power rails are operational
ACT CTRL
Active Control
Red
Initializing
Solid Green
FPGA has configured and the control system is
communicating with the card
Flashing Green
Alarm condition on the card
ACT OUT
Active Output Warning
Yellow
Output on card being used by one or more
outputs
Module LEDs
See Module LEDs.
Controllable Parameters
For Output Modules, the Controllable Parameters List is a multilevel structure that includes all of the
available parameters, arranged into groupings.
Parameter Notes
Parameters can be enabled and/or changed via CCS Navigator or the IP3 Controller.
Parameters marked with the [RO] designator are "read-only."
Parameters marked
Expansion Modules Only
apply only to expansion modules such as PX-
HSR8O2DS-OBG Output Module, PX-HSR8C2DS-OBG Output Module, and PX-HSR1D2D-OBG Output
Module (on page 137)
Parameters marked
Modules with SFPs Only
apply only to optical modules such as PX-HSR16O-OBG
Output Module.