Platinum™ IP3
Installation and Operation Manual
Alarm Expansion Module (PX-ALARM)
© 2016 Imagine Communications Corp.
Proprietary and Confidential.
September 2016 | Page 64
Micro-Dsub Connector Pinouts
Table 19:
GPI Pinout
Pin Description
Pin Description
1
Remote in 3
14
Normally closed (Power supply alarm)
2
Common (User-defined 1)
15
Normally open (Power supply alarm)
3
Normally closed (User-defined 1)
16
Common (Power supply alarm)
4
Normally open (User-defined 1)
17
Normally closed (Fan alarm)
5
Common (User-defined 2)
18
Normally open (Fan alarm)
6
Normally closed (User-defined 2)
19
Common (Fan alarm)
7
Normally open (User-defined 2)
20
Floating
8
Common (User-defined 3)
21
Remote in 1
9
Normally closed (User-defined 3)
22
GND (Common in 1)
10
Normally open (User-defined 3)
23
Floating
11
Common (User-defined 4)
24
Remote in 2
12
Normally closed (User-defined 4)
25
GND (Common in 2 and 3)
13
Normally open (User-defined 4)
Parameters
PX-ALARM-DATA Parameters
Table 20:
PX-ALARM-DATA Parameters
Category
Name
Description
Type
Options
Root
Power Good
Informs the user if board is experiencing
any power issues
RO
No
Yes
PS Alarm
Reports if any of the power supplies have
failed or if there is a loss of power
redundancy.
RO
No
Yes
PSU
PS Zone Redundancy
PS Zone Redundancy (1-4)
(Table Parameter)
Reports Power Zone redundancy status
RO
No
Yes
Power Supply
PS Status (1-16)
Reports individual power supply status
RO
Good
Failed
Not Present