Platinum™ IP3
Installation and Operation Manual
Output Monitoring Modules
© 2016 Imagine Communications Corp.
Proprietary and Confidential.
September 2016 | Page 69
When routing external sources to monitor output, routing for external Inputs 1-4 is fixed. You can
only route as follows:
Slot 6
Slot 7
IN 1
OUT 1
IN 3
OUT 3
IN 2
OUT 2
IN 4
OUT 4
Any cross routing (for example Input 1 to Output 2) is locked.
Table 25:
PX-HSRAEC-OM Video Specifications
Items
Specification
Number of External Inputs
4
Number of Outputs
4
Coaxial Connector
HD-BNC
Impedance
75 ohms
Signal Type
SMPTE 424M, SMPTE 292M, SMPTE 259M, SMPTE
344M, DVB-ASI, 3Mb/s to 3Gb/s
Nominal internal input amplitude
800mVp-p +/- 10%
External input amplitude
800mVp-p +/- 10%
Max. input cable length (1694A)
Up to 150m for 3Gbps
Up to 200m for 1.5Gbps
Up to 400m for 270Mbps
Reclocking
Automatic for data rates defined by SMPTE
424/259/292/344, DVB-ASI.
Bypass for all nonstandard rates
Return Loss
15dB up to 1.5GHz
10dB from 1.5GHz to 3GHz
Output Jitter
< .2UI @ frequency tested
Output Amplitude
800mVp-p ± 10%
DC offset
0V ± 0.5V
Rise/Fall times
400ps – 1500ps for 270Mbps
< 270pS for 1.5Gbps
< 135pS for 3Gbps
Overshoot
< 10% of amplitude
Table 26:
PX-HSRAEC-OM LED Indicators
LED Indicator
Function
Description
EXT IN 1
Signal Presence
Active signal on this input (green)
EXT IN 2
Signal Presence
Active signal on this input (green)
EXT IN 3
Signal Presence
Active signal on this input (green)
EXT IN 4
Signal Presence
Active signal on this input (green)
POWER
Power Supply Indicator
+24V power rails are operational