Platinum™ IP3
Installation and Operation Manual
Alarm Expansion Module (PX-ALARM)
© 2016 Imagine Communications Corp.
Proprietary and Confidential.
September 2016 | Page 62
GPI Output Alarms (User Configurable Alarms)
The Resource Module (PX-RES) communicates the status of alarm conditions within the IP3 frame via
user-defined GPI outputs 1 through 4 to the PX-ALARM module. When a GPI Output is asserted, the
corresponding GPO LED is lit on the PX-ALARM module.
Figure 20:
User Definable Alarms
Fan Failure Alarm
Rear Fans status is reported via the PX-ALARM-DATA module. You can see status for individual rear fans
as well as individual fan speed.
If any of the Rear fan modules have a failure:
This alarm condition is reported to the Platinum IP3 Controller via the Resource card
The
FAN ALM
LED on the PX-ALARM module is illuminated
The
Fan Alarm
GPI Output is asserted/triggered.