Platinum™ IP3
Installation and Operation Manual
Alarm Expansion Module (PX-ALARM)
© 2016 Imagine Communications Corp.
Proprietary and Confidential.
September 2016 | Page 65
Category
Name
Description
Type
Options
PS Zone
The Zone the power supply provides power
to
RO
Zone 1
Zone 2
Zone 3
Zone 4
PS +5VL Failed
Reports if the power supply is providing
5VL power.
RO
No
Yes
PS +24VL Failed
Reports if the power supply is providing
24VL power.
RO
No
Yes
PS Fan Failed
Reports if the power supply fan is in
working order.
RO
No
Yes
PS Ambient Temperature
Reports the temperature of the air coming
into the PSU Fan.
RO
-55~125C
PS Secondary Temperature
Reports the temperature of the air coming
out of the PSU Fan.
RO
-55~125C
PS +5VL Current
5V current is being drawn from the power
supply.
RO
0~100Amps
PS +24VL Current
24V current is being drawn from the power
supply.
RO
0~100Amps
Alarm
Alarm
External Alarm Enable
Enable external alarm. Set based on
whether the alarm is enabled, GPI status,
and trigger value.
RW
No
Yes
N/A
External Alarm Trigger
Set the alarm trigger
RW
Low
High
External Alarm
Reports if an external alarm has been
enabled
RO
No
Yes
User Configurable Alarm
User Configurable Alarm (1-4)
Triggers a GPO to an external system
RW
No
Yes
N/A
Rear Fans
Rear Fan Speed (1-7)
Reports the speed in RPM of the fan
RO
0-7000rpm
Rear Fan Failed (1-7)
Set to yes if there is a loss of
communication to the fan or fan is spinning
too slow.
RO
No
Yes
PX-ALARM-ATDM Parameters
Table 21:
PX-ALARM-ATDM Parameters
Name
Description
Type
Options
Power Good
Reports if the board is experiencing any power
issues
RO
No
Yes
TDM Cable Present (1-4)
(Table Parameter)
Set to yes if there is a densishield cable plugged in.
RO
No
Yes