Platinum™ IP3
Installation and Operation Manual
PX-FRONT-FAN and PX-REAR-FAN Modules
© 2016 Imagine Communications Corp.
Proprietary and Confidential.
September 2016 | Page 291
Rear Fans Status in the Web UI
The Controller Web UI reports
Rear Fans
status in the
PX-ALARM-DATA
module, accessible by going to
the List of Modules > Control Cards and clicking
Open Module
against
PX-ALARM-DATA
.
A 28 RU frame displays status for 7 of its rear fans. A 15 RU frame displays status for its 4 rear fans, and
Fans 5/6/7 will show as N/A. You can see individual fan speed, as well as whether any of the fans have
failed.
Figure 135:
Rear Fan Status for a 15 RU Frame
Servicing the Fans
The following fan parts can be replaced in the field:
PX-FRONT-FAN array module
Individual front fan units
Individual rear fan units
Replacing a Front Fan Module
To replace a Front Fan module, follow these steps:
1.
After opening the front door of the frame, locate the faulty fan module.
2.
Loosen the two thumbscrews, and then swing the module to the left.
Figure 136:
Front Fan Module Array (Top Module Shown)