September 2016 | Page 183
Name
Description
Type
Options
Force Freeze Mode
Specifies the type of freeze,
field 1, field 2 or frame
RW
Field 1
Field 2
Frame
Loss of Video Mode
Specifies operation on loss of
video, pass, black or freeze.
RW
Pass
Black
Freeze
Fast Switch
Enable fast switching
See Fast Video Switch (on
page 184)
RW
No
Yes
Frame Sync/Mux Mode
Sets the operational mode of
the frame sync delay or sync.
See Video Frame
Synchronization (on page 189)
RW
FS: Sync Mode
FS: Delay Mode
Mux: Auto Detect
Mux: Always On
Bypass
Frame Sync/Mux Status
Reflects operational mode
status based on license, mode
of operation, presence, and
rate of Reference signal.
RW
FS: Ext Lock
FS: Local Lock
FS: Delay Forced
FS: Delay Rate
Mismatch
Unprocessed Outputs
Name
Description
Type
Options
Unprocessed
Outputs
Reclocked Signal Presence
Reports the presence of the
SDI signal that becomes one
of the unprocessed outputs
RO
No
Yes
Reclocked Data Rate
Reports the data rate of the
SDI signals that becomes one
of the unprocessed outputs.
RO
Unknown
SD
HD
3G
Reclocked Output Swing
For Back modules featuring
electrical unprocessed
outputs, only.
Used to set the output swing.
Default is 800mV.
RW
800mV
1600mV