Failsafe Mode
To put an Input Module in Failsafe Mode:
1.
Unplug the board
2.
Set the Failsafe jumper.
3.
Wait 10 seconds
4.
Insert the board again
The above procedure applies to the following Input Modules
PX-HSR9C-IBG Input Module (on page
PX-HSR9O-IBG Input Module (on page 129)
PX-HSR9C1D-IBG Input Module (on page 131)
PX-HSR9O1D-IBG Input Module (on page 131)
Signal Presence and LEDs
Each of the nine input channels on the Input Module provides signal presence reporting via card edge
LEDs and the control software. Both have the ability to be disabled or enabled through the control
software, along with a user-selectable hysteresis period.
Module LEDs
See Module LEDs (on page 298).
System LEDs
There are three system indicator LEDs on the front edge of the module:
Table 46:
Module System LEDs
LED
DESCRIPTION
INPUT 1-9
Signal Presence
Green
Signal Present
Slow Flash
Valid Signal present but not locked
Solid On
Valid Signal present and locked
POWER
Power Supply indicator
Green
+24V power rails are operational
ACT CTRL
Active Control
Red
Initializing