Platinum™ IP3
Installation and Operation Manual
Digital Video Modules
© 2016 Imagine Communications Corp.
Proprietary and Confidential.
September 2016 | Page 138
The PX-HSR1D2D-OBG has 3 DensiShield connectors mounted on the metal back panel of the back
module.
There is 1 DensiShield port on the module, which can output up to 8 electrical outputs.
There are another 2 DensiShield ports which are intended for expansion. However, if expansion is not
used, then the DensiShield output port can be connected to another PX-UCIP module.
Power Consumption
Table 70:
PX-HSR1D2D-OBG Power Consumption
24V Power Rail
14.1W
5V Power Rail
0.43W
Total Power
14.53W
PX-HSR1D2D-OBG Output Module
The
PX-HSR1D2D-OBG
Module can be controlled via the
Controller
. When you access a module (by
clicking on it in the list of Output Modules), its parameters are displayed. The total number of PX-
HSR1D2D-OBGs in the frame is also displayed on the left.