Platinum™ IP3
Installation and Operation Manual
Module LEDs
© 2016 Imagine Communications Corp.
Proprietary and Confidential.
September 2016 | Page 298
Module LEDs
Card Edge LED Diagnostics
There are multiple card edge LEDs on IP3 Input Modules (PX-IB) (on page 111) and Output Modules (PX-
OB) (see "Input Modules (PX-IB)" on page 111) Modules.
LED Labels
LEDs are labeled as follows:
Input Modules
INPUT 1
to
INPUT 9
Output Modules
OUTPUT 1
to
OUTPUT 16
Under normal working conditions, all the LEDs are used to indicate signal presence status.
Under certain abnormal conditions, for instance if a module is improperly installed, or the wrong kind of
module is plugged in a slot (designed to host another type of module), card edge LEDs are used to show
diagnostic information.
LED States
There are three possible states indicated by each LED:
Table 130:
LED States
State
Description
Off
No signal present
On
Signal present and reclocker locked to signal
Flashing
Signal present but reclocker could not lock to signal
Input Module LEDs
(on page
Input 1 and Input 2 (on page
Input 3, Input 4, Input 5 (on page 299)
Input 6, Input 7, Input 8, Input 9 (on page 299)
Output Module LEDs
(on page
Output 1 - Output 6 (on page
Output 7, Output 8, Output 9 (on page 300)
Output 13, Output 14, Output 15, Output 16 (on page 300)