Table
3.
POST
error
messages
(continued)
v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
Error
code
Description
Action
184
The
power-on
password
information
stored
in
the
computer
has
been
removed.
1.
Run
the
Configuration/Setup
Utility
program,
select
Load
Default
Settings
,
and
save
the
settings.
2.
Reseat
the
battery.
3.
Replace
the
battery.
4.
(Trained
service
technician
only)
Replace
the
system
board.
187
The
VPD
serial
number
is
not
set.
Note:
The
system
serial
number
is
set
in
the
VPD
EEPROM
at
the
time
of
manufacturing.
If
the
system
board
has
been
replaced,
the
system
serial
number
will
be
invalid
and
must
be
reset.
1.
Restart
the
computer.
2.
Update
the
BIOS
code
to
set
the
serial
number.
3.
(Trained
service
technician
only)
Replace
the
system
board.
189
An
attempt
has
been
made
to
access
the
computer
with
an
incorrect
password
three
times.
Restart
the
computer
and
enter
the
administrator
password;
then,
run
the
Configuration/Setup
Utility
program
and
change
the
power-on
password.
201
An
error
occurred
during
the
memory
controller
test.
This
error
can
be
caused
by:
v
Incorrectly
installed
memory
v
A
failing
memory
module
v
A
system
board
problem
1.
If
you
just
installed
memory,
make
sure
that
the
new
memory
is
correct
for
the
computer.
2.
Reseat
the
DIMM.
3.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
computer
each
time:
a.
DIMM
b.
(Trained
service
technician
only)
System
board.
289
An
error
occurred
during
POST
memory
tests
and
a
DIMM
was
disabled.
1.
If
you
just
installed
memory,
make
sure
that
the
new
memory
is
correct
for
the
computer.
2.
If
the
DIMM
was
disabled
by
the
user,
run
the
Configuration/Setup
Utility
program
and
enable
the
DIMM.
3.
Reseat
the
DIMM.
4.
Replace
the
DIMM.
20
IBM
IntelliStation
M
Pro
Type
6218
and
9236:
Problem
Determination
and
Service
Guide
Summary of Contents for IntelliStation M Pro 6218
Page 1: ...IBM IntelliStation M Pro Type 6218 and 9236 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...IBM IntelliStation M Pro Type 6218 and 9236 Problem Determination and Service Guide...
Page 8: ...vi IBM IntelliStation M Pro Type 6218 and 9236 Problem Determination and Service Guide...
Page 16: ...xiv IBM IntelliStation M Pro Type 6218 and 9236 Problem Determination and Service Guide...
Page 26: ...10 IBM IntelliStation M Pro Type 6218 and 9236 Problem Determination and Service Guide...
Page 140: ...124 IBM IntelliStation M Pro Type 6218 and 9236 Problem Determination and Service Guide...
Page 162: ...146 IBM IntelliStation M Pro Type 6218 and 9236 Problem Determination and Service Guide...
Page 167: ......
Page 168: ...Part Number 31R1998 Printed in USA 1P P N 31R1998...