v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
Error
code
Description
Action
035-279-001
Adapter
Cache
test
error.
1.
Update
the
ServeRAID
adapter
firmware
(see
2.
Reseat
the
ServeRAID
adapter.
3.
Replace
the
ServeRAID
adapter.
035-280-001
Adapter
Drive
test
error.
Replace
the
attached
drive.
035-281-001
Adapter
Drive
error.
Replace
the
attached
drive.
035-282-001
Adapter
Parameters
set
error.
1.
Update
the
ServeRAID
adapter
firmware
(see
2.
Reseat
the
ServeRAID
adapter.
3.
Replace
the
ServeRAID
adapter.
035-283-001
Adapter
Battery
error.
Replace
the
battery
module
on
the
ServeRAID
adapter.
035-xxx-099
No
adapters
were
found.
Reseat
the
following
components:
1.
ServeRAID
adapter
2.
Adapter
cable
035-xxx-s99
Failed
RAID
test
on
PCI
slot
S.
S
=
number
of
failing
PCI
slot.
1.
Reseat
the
following
components:
a.
ServeRAID
adapter
b.
Adapter
cable
2.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
computer
each
time:
a.
ServeRAID
adapter
b.
Adapter
cable
c.
(Trained
service
technician
only)
System
board
035-xxx-cnn
c
=
ServeRAID
channel
number,
nn
=
SCSI
ID
of
failing
fixed
disk
drive.
1.
Check
the
system-event/error
log
before
replacing
a
FRU.
2.
Reseat
the
hard
disk
drive
on
channel
C,
SCSI
ID
nn.
3.
Replace
the
hard
disk
drive
on
channel
C,
SCSI
ID
nn.
035-xxx-snn
S
=
number
of
failing
PCI
slot,
nn
=
SCSI
ID
of
failing
fixed
disk.
1.
Check
the
system-event/error
log
before
replacing
a
FRU.
2.
Reseat
the
SCSI
disk
with
ID
nn.
3.
Replace
the
SCSI
disk
with
ID
nn.
44
IBM
IntelliStation
M
Pro
Type
6218
and
9236:
Problem
Determination
and
Service
Guide
Summary of Contents for IntelliStation M Pro 6218
Page 1: ...IBM IntelliStation M Pro Type 6218 and 9236 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...IBM IntelliStation M Pro Type 6218 and 9236 Problem Determination and Service Guide...
Page 8: ...vi IBM IntelliStation M Pro Type 6218 and 9236 Problem Determination and Service Guide...
Page 16: ...xiv IBM IntelliStation M Pro Type 6218 and 9236 Problem Determination and Service Guide...
Page 26: ...10 IBM IntelliStation M Pro Type 6218 and 9236 Problem Determination and Service Guide...
Page 140: ...124 IBM IntelliStation M Pro Type 6218 and 9236 Problem Determination and Service Guide...
Page 162: ...146 IBM IntelliStation M Pro Type 6218 and 9236 Problem Determination and Service Guide...
Page 167: ......
Page 168: ...Part Number 31R1998 Printed in USA 1P P N 31R1998...