Table
3.
POST
error
messages
(continued)
v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only),”
that
step
must
be
performed
only
by
a
trained
service
technician.
Error
code
Description
Action
1162
The
serial
port
configuration
conflicts
with
another
device
in
the
system.
1.
Make
sure
that
the
IRQ
and
I/O
port
assignments
needed
by
the
serial
port
are
available.
2.
If
all
interrupts
are
being
used
by
adapters,
remove
an
adapter
to
make
an
interrupt
available
to
the
serial
port,
or
force
other
adapters
to
share
an
interrupt.
3.
Make
sure
that
the
serial
port
setting
is
correct
in
the
Configuration/Setup
Utility
program.
If
the
setting
is
not
correct,
change
it
and
save
the
settings.
4.
(Trained
service
technician
only)
Replace
the
system
board.
1762
A
hard
disk
drive
configuration
error
occurred.
1.
Make
sure
that
the
hard
disk
drive
is
set
correctly
in
the
Configuration/Setup
Utility
program.
2.
Reseat
the
hard
disk
drive
cable.
3.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
computer
each
time:
a.
Hard
disk
drive
b.
Hard
disk
drive
cable
c.
(Trained
service
technician
only)
System
board
178x
An
error
occurred
during
the
hard
disk
drive
x
test
(x
=
0
to
3).
1.
Reseat
the
hard
disk
drive
x
cable.
2.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
computer
each
time:
a.
Hard
disk
drive
x
b.
Hard
disk
drive
cable
x
c.
(Trained
service
technician
only)
System
board
1801
A
PCI
adapter
has
requested
memory
resources
that
are
not
available.
1.
Change
the
order
of
the
adapters
in
the
PCI
or
PCI
Express
slots.
Make
sure
that
the
boot
device
is
positioned
early
in
the
scan
order
(see
the
User’s
Guide
for
information
about
the
scan
order).
2.
Make
sure
that
the
settings
for
the
adapter
and
all
other
adapters
in
the
Configuration/Setup
Utility
program
are
correct.
If
the
memory
resource
settings
are
not
correct,
change
them.
3.
If
all
memory
resources
are
being
used,
remove
an
adapter
to
make
memory
available
to
the
adapter.
Disabling
the
BIOS
on
the
adapter
should
correct
the
error.
See
the
documentation
that
comes
with
the
adapter.
22
IBM
IntelliStation
M
Pro
Type
6218
and
9236:
Problem
Determination
and
Service
Guide
Summary of Contents for IntelliStation M Pro 6218
Page 1: ...IBM IntelliStation M Pro Type 6218 and 9236 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...IBM IntelliStation M Pro Type 6218 and 9236 Problem Determination and Service Guide...
Page 8: ...vi IBM IntelliStation M Pro Type 6218 and 9236 Problem Determination and Service Guide...
Page 16: ...xiv IBM IntelliStation M Pro Type 6218 and 9236 Problem Determination and Service Guide...
Page 26: ...10 IBM IntelliStation M Pro Type 6218 and 9236 Problem Determination and Service Guide...
Page 140: ...124 IBM IntelliStation M Pro Type 6218 and 9236 Problem Determination and Service Guide...
Page 162: ...146 IBM IntelliStation M Pro Type 6218 and 9236 Problem Determination and Service Guide...
Page 167: ......
Page 168: ...Part Number 31R1998 Printed in USA 1P P N 31R1998...