Erasing
a
lost
or
forgotten
password
(clearing
CMOS)
If
the
power-on
or
administrator
password
is
lost
or
forgotten,
you
can
regain
access
to
the
computer
through
one
of
the
following
methods:
v
If
you
have
forgotten
the
power-on
password
and
an
administrator
password
is
set,
type
the
administrator
password
at
the
power-on
prompt;
then,
start
the
Configuration/Setup
Utility
program
and
change
the
power-on
password
(see
the
User’s
Guide
on
the
IBM
IntelliStation
Documentation
CD
for
more
information).
v
Remove
the
battery
and
then
reinstall
the
battery
(see
and
v
Clear
CMOS
settings
by
changing
the
position
of
the
CMOS
recovery
jumper
(JP1).
To
set
the
CMOS
recovery
jumper
and
erase
a
forgotten
password,
complete
the
following
steps:
1.
Read
the
safety
information
that
begins
on
page
and
2.
Turn
off
the
computer
and
all
attached
devices.
3.
Disconnect
the
power
cord.
4.
Remove
the
cover
and
hard
disk
drive
bracket
(if
one
is
installed).
5.
Locate
the
CMOS
recovery
jumper
(JBAT1)
on
the
system
board
(see
removing
any
adapters
that
impede
access
to
the
jumper.
6.
Move
the
CMOS
recovery
jumper
from
pins
1
and
2
to
pins
2
and
3.
7.
Wait
60
seconds;
then,
return
the
CMOS
recovery
jumper
to
pins
1
and
2.
8.
Replace
any
adapters
that
were
removed;
then,
replace
the
hard
disk
drive
bracket
(if
one
was
removed)
and
the
cover.
9.
Connect
the
computer
to
a
power
source,
keyboard,
monitor,
and
mouse.
Note:
You
can
now
start
the
computer
one
time
and
start
the
Configuration/Setup
Utility
program
without
having
to
use
the
power-on
password.
At
this
time,
you
can
either
delete
the
old
power-on
password
or
set
a
new
power-on
password.
If
you
do
not
change
or
delete
the
password,
the
next
time
you
start
the
computer
the
original
power-on
password
will
be
reinstated.
10.
Turn
on
the
computer
and
start
the
Configuration/Setup
Utility
program.
11.
Follow
the
instructions
to
erase
the
existing
password
or
to
create
a
new
password.
12.
Click
Save
Settings
and
exit
the
Configuration/Setup
Utility
program.
Solving
power
problems
Power
problems
can
be
difficult
to
solve.
For
example,
a
short
circuit
can
exist
anywhere
on
any
of
the
power-distribution
buses.
Usually,
a
short
circuit
will
cause
the
power
subsystem
to
shut
down
because
of
an
overcurrent
condition.
To
diagnose
a
power
problem,
use
the
following
general
procedure:
1.
Turn
off
the
computer,
and
disconnect
all
ac
power
cords.
2.
Check
for
loose
cables
in
the
power
subsystem.
Also
check
for
short
circuits,
for
example,
if
there
is
a
loose
screw
causing
a
short
circuit
on
a
circuit
board.
62
IBM
IntelliStation
M
Pro
Type
6218
and
9236:
Problem
Determination
and
Service
Guide
Summary of Contents for IntelliStation M Pro 6218
Page 1: ...IBM IntelliStation M Pro Type 6218 and 9236 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...IBM IntelliStation M Pro Type 6218 and 9236 Problem Determination and Service Guide...
Page 8: ...vi IBM IntelliStation M Pro Type 6218 and 9236 Problem Determination and Service Guide...
Page 16: ...xiv IBM IntelliStation M Pro Type 6218 and 9236 Problem Determination and Service Guide...
Page 26: ...10 IBM IntelliStation M Pro Type 6218 and 9236 Problem Determination and Service Guide...
Page 140: ...124 IBM IntelliStation M Pro Type 6218 and 9236 Problem Determination and Service Guide...
Page 162: ...146 IBM IntelliStation M Pro Type 6218 and 9236 Problem Determination and Service Guide...
Page 167: ......
Page 168: ...Part Number 31R1998 Printed in USA 1P P N 31R1998...