3746-900 FRU Exchange
MAP: Ready LED ON
You are here because the 3746-900 has:
¹
Its ready LED ON
¹
A character displayed in the "Service processor not accessible" window on the 3746-900 control panel.
001
There is no link between the 3746-900 and the service processor.
Is the CBSP and/or its associated TIC3 and/or the basic board in your FRU list?
Yes No
002
You have another problem on your 3746-900. Go to “MAP 2750: 3746-900 Permanent Service
Processor Link Problem” on page 2-94 for problem determination.
003
¹
Select the FRU in your FRU list with the highest fault probability.
– If the TIC3 has the highest fault probability, go to Step 004
– If the CBSP has the highest fault probability, go to Step 018 on page 1-53
– If the basic board has the highest fault probability, go to “MAP: 3746-900 in Offline Mode” on
page 1-124.
004
¹
Ask the customer to stop traffic on the TIC3 of the CBSP.
¹
Go to Chapter 4, “3746-900 FRU Exchange” on page 4-1 for the TIC3 replacement. After replacing
the TIC3, continue this procedure.
Did you replace the TIC3 by a new one?
Yes No
005
Go to Step 015 on page 1-53.
006
¹
Press the 'Exit' key on the 3746-900 control panel.
Is 00000000 displayed on the 3746-900 control panel?
Yes No
007
Go to Step 010.
008
Is there a character displayed in the "Service processor not accessible" window on the 3746-900
control panel?
Yes No
009
¹
The TIC3 of the CBSP has been successfully changed. There is no diagnostic for this FRU.
¹
Since you were here because there was no link between the 3746-900 and the service
processor, you have solved your problem.
¹
Go to Step 025 on page 1-54.
010
¹
Changing the TIC3 did not solve the problem. Reinstall the TIC3 previously removed using the fol-
lowing steps.
¹
Go to Chapter 4, “3746-900 FRU Exchange” on page 4-1 for the FRU replacement, then after FRU
replacement return here to continue this procedure.
(Step 010 continues)
1-52
3746-900: Service Guide
Summary of Contents for FlashSystem 900
Page 1: ...3746 Nways Multiprotocol Controller Model 900 Service Guide SY33 2116 02...
Page 2: ......
Page 3: ...3746 Nways Multiprotocol Controller Model 900 Service Guide SY33 2116 02...
Page 14: ...xii 3746 900 Service Guide...
Page 16: ...xiv 3746 900 Service Guide...
Page 22: ...xx 3746 900 Service Guide...
Page 29: ...Safety Figure 0 3 Ground Wire Connection On Controller Expansion SAFETY xxvii...
Page 60: ...Safety lviii 3746 900 Service Guide...
Page 61: ...Safety SAFETY lix...
Page 62: ...Safety lx 3746 900 Service Guide...
Page 63: ...Safety SAFETY lxi...
Page 64: ...Safety lxii 3746 900 Service Guide...
Page 65: ...Safety SAFETY lxiii...
Page 66: ...Safety lxiv 3746 900 Service Guide...
Page 67: ...Safety...
Page 68: ...Safety lxvi 3746 900 Service Guide...
Page 69: ...Safety SAFETY lxvii...
Page 70: ...Safety lxviii 3746 900 Service Guide...
Page 71: ...Safety...
Page 72: ...Safety lxx 3746 900 Service Guide...
Page 73: ...Safety SAFETY lxxi...
Page 74: ...Safety lxxii 3746 900 Service Guide...
Page 75: ...Safety SAFETY lxxiii...
Page 76: ...Safety lxxiv 3746 900 Service Guide...
Page 77: ...Safety SAFETY lxxv...
Page 78: ...Safety lxxvi 3746 900 Service Guide...
Page 92: ...Safety xc 3746 900 Service Guide...
Page 94: ...Safety xcii 3746 900 Service Guide...
Page 129: ...3746 900 FRU Exchange 010 continued Go to MAP Ready LED ON on page 1 52 Chapter 1 START 1 35...
Page 276: ...3746 900 MAPs Figure 2 6 CP2 Circuit 2 18 3746 900 Service Guide...
Page 325: ...3746 900 MAPs 026 continued Go to Step 014 on page 2 65 Chapter 2 MAPs for FRU Isolation 2 67...
Page 340: ...3746 900 MAPs 113 continued Go to Step 001 on page 2 68 2 82 3746 900 Service Guide...
Page 414: ...Service Processor MAPs 2 156 3746 900 Service Guide...
Page 484: ...FRU Exchange Figure 4 16 3746 Model 9x0 CBSP Cassette 4 18 3746 900 Service Guide...
Page 495: ...FRU Exchange Figure 4 23 3746 900 Rear of DC Power Box Chapter 4 3746 900 FRU Exchange 4 29...
Page 510: ...FRU Exchange Figure 4 39 3746 900 LIC16 Coupler 4 44 3746 900 Service Guide...
Page 520: ...FRU Exchange Figure 4 45 3746 900 Transformer Handling 4 54 3746 900 Service Guide...
Page 522: ...FRU Exchange 4 56 3746 900 Service Guide...
Page 542: ......
Page 545: ......