FRU Exchange
Exchange an Enclosure (Basic or Expansion)
Important
Check that the 'Power Control' display is
set to local (3) on the control panel.
If not, do the following:
¹
Press the 'Power Control' key until (3) is
displayed in the power control window.
¹
Press the 'Validate' key.
If the state of the machine does not allow you
to display or to change the 'Power control'
mode, continue with the following procedure.
1. If the machine has its:
¹
Ready LED ON, go to step 2.
¹
Otherwise go to step 4.
2. Press the 'standby' key.
3. When the machine is in standby mode with its
Standby LED ON, go to the next step.
4. Switch OFF the main circuit breaker CB1
.1/
of the ACPW and, if installed, of the second
ACPW/DCPW.
5. Locate the enclosure that you want removed
using Figure 4-9 on page 4-8.
6. From the front machine:
a. Remove the internal covers to have
access to the CSCE cassette.
b. WARNING: Use the ESD kit and proce-
dures.
c. Remove the CSCE, SPS, and all the PRC
cassettes from the enclosure.(See the
CSCE, SPS and PRCs exchange proce-
dure for details).
d. Disconnect the two ground straps from the
enclosure.
.3/
F r o n t V i e w
7. From the rear of the machine:
a. Remove the internal cover to gain access,
to the SPD1 cassette if you change the
basic enclosure, or to the SPD2 cassette
if you exchange the expansion enclosure.
b. Unplug all the cables from the SPD1 or
SPD2 cassette.
c. Unplug all cables from the coupler cas-
settes. (See “Exchange an
ESCC/ESCC2” on page 4-32 and
“Exchange a TIC3” on page 4-51)
d. If you exchange the basic enclosure:
remove the SPD1 and all the coupler cas-
settes from the enclosure (see the SPD1
and coupler exchange procedure for
details).
If you exchange the expansion enclosure:
Remove the SPD2 and all the coupler
cassettes from the enclosure (see SPD2
and coupler exchange procedure for
details).
e. Remove the 8 screws which secure the
enclosure.
.4/
8. Pull the enclosure out from the machine.
4-30
3746-900: Service Guide
Summary of Contents for FlashSystem 900
Page 1: ...3746 Nways Multiprotocol Controller Model 900 Service Guide SY33 2116 02...
Page 2: ......
Page 3: ...3746 Nways Multiprotocol Controller Model 900 Service Guide SY33 2116 02...
Page 14: ...xii 3746 900 Service Guide...
Page 16: ...xiv 3746 900 Service Guide...
Page 22: ...xx 3746 900 Service Guide...
Page 29: ...Safety Figure 0 3 Ground Wire Connection On Controller Expansion SAFETY xxvii...
Page 60: ...Safety lviii 3746 900 Service Guide...
Page 61: ...Safety SAFETY lix...
Page 62: ...Safety lx 3746 900 Service Guide...
Page 63: ...Safety SAFETY lxi...
Page 64: ...Safety lxii 3746 900 Service Guide...
Page 65: ...Safety SAFETY lxiii...
Page 66: ...Safety lxiv 3746 900 Service Guide...
Page 67: ...Safety...
Page 68: ...Safety lxvi 3746 900 Service Guide...
Page 69: ...Safety SAFETY lxvii...
Page 70: ...Safety lxviii 3746 900 Service Guide...
Page 71: ...Safety...
Page 72: ...Safety lxx 3746 900 Service Guide...
Page 73: ...Safety SAFETY lxxi...
Page 74: ...Safety lxxii 3746 900 Service Guide...
Page 75: ...Safety SAFETY lxxiii...
Page 76: ...Safety lxxiv 3746 900 Service Guide...
Page 77: ...Safety SAFETY lxxv...
Page 78: ...Safety lxxvi 3746 900 Service Guide...
Page 92: ...Safety xc 3746 900 Service Guide...
Page 94: ...Safety xcii 3746 900 Service Guide...
Page 129: ...3746 900 FRU Exchange 010 continued Go to MAP Ready LED ON on page 1 52 Chapter 1 START 1 35...
Page 276: ...3746 900 MAPs Figure 2 6 CP2 Circuit 2 18 3746 900 Service Guide...
Page 325: ...3746 900 MAPs 026 continued Go to Step 014 on page 2 65 Chapter 2 MAPs for FRU Isolation 2 67...
Page 340: ...3746 900 MAPs 113 continued Go to Step 001 on page 2 68 2 82 3746 900 Service Guide...
Page 414: ...Service Processor MAPs 2 156 3746 900 Service Guide...
Page 484: ...FRU Exchange Figure 4 16 3746 Model 9x0 CBSP Cassette 4 18 3746 900 Service Guide...
Page 495: ...FRU Exchange Figure 4 23 3746 900 Rear of DC Power Box Chapter 4 3746 900 FRU Exchange 4 29...
Page 510: ...FRU Exchange Figure 4 39 3746 900 LIC16 Coupler 4 44 3746 900 Service Guide...
Page 520: ...FRU Exchange Figure 4 45 3746 900 Transformer Handling 4 54 3746 900 Service Guide...
Page 522: ...FRU Exchange 4 56 3746 900 Service Guide...
Page 542: ......
Page 545: ......